Model / Specification |
LP-150-12 |
LP-150-24 |
Output |
DC Output Voltage |
12V |
24V |
Output Voltage tolerance |
± 1% |
± 1% |
Rated Output Current |
12.5A |
6.25A |
Output Current Range |
0-12.5A |
0-6.25A |
DC Output Power |
150 W |
150 W |
Tripple and Noise |
120mVp-p |
240mVp-p |
Adjustable Range for DC Voltage |
11.4-13.2V |
20.5-26.5V |
Input |
AC Input Voltage Range |
85-132VAC/176-264VAC selected by swith or 248-373VDC 47~63Hz; |
AC input current |
3A/115VAC 1.5A/230VAC |
Efficiency |
83% |
85% |
AC Inrush Current |
Cold-Start Current: 10A/115V, 20A/230V |
Leakage Current |
<2mA/240VAC |
Protection charateristic |
Overload Protection |
110%-150% |
Protection mode: cut off output and restart |
Over Voltage Protection |
13.8-16.2V |
27-30V |
Protection mode: cut off output and reset automatically |
Environment |
Work Temperature Humidity |
-10°C~+50°C , 20%~90%RH |
Storage Temperature Humidity |
`-20°C~+85°C, 10%~95%RH |
Shock resistance |
10~500Hz, 2G 10min,/1cycle,duration:60min each shaft |
Safety |
Voltage withstand capacity |
Input-output:2KVAC Input-earth:1.5KVAC Output-earth:0.5KVAC |
Insulation resistance |
Input-output, Input-earth ,Output-earth:100M Ohms/500VDC |
Executive Stantand |
Safety Standards |
CE |
EMC Standards |
Design refer to FCC part 15J Conduction Class B |
Others |
Weight |
0.41KGS |
Package |
30pcs/ctn 37*30*24.5 |
size |
83*49*100(L*W*H) |
Notes |
1. All parameters except special situtation, are meaured under 230VAC voltage input and rated load at 25°C. 2. The ripple and noise voltage are measured in condition capacitance of 0.1μ and 47μ are applied to ends of 12inch twisted-pair of 20MHZ bandwidth oscilloscope. 3.The tolerance is the sum of setting voltage error , voltage and current regulation factor. |