LAQUA K-11/CA-11/NO3-11/NA-11

LAQUA K-11/CA-11/NO3-11/NA-11

Category: Horiba Products Available
For more information, visit our official website at eccsb.com.my

Description

Potassium Ion
Model: K-11
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 mL (0.05 mL with Sampling Sheet B)
Measurement Range: 4 to 9900 ppm (mg/L)
(0.1 to 250 mmol/L)
2 to 5000 kg/10a (soil/water ratio 1:5)
Resolution: 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm 
1000 to 9900 ppm: 100 ppm
Accuracy Maximum: ±10% of actual value
Calibration Points: 2
Accessories Included:
150 & 2000 ppm Standard Solutions (14 mL each)
  • Sampling Sheet B (5 pcs)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals
  • Storage Case
 
Calcium Ion
Model: Ca-11
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 mL (0.05 mL with Sampling Sheet B)
Measurement Range: 4 to 9900 ppm (mg/L)
(0.1 to 250 mmol/L)
Resolution: 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm 
1000 to 9900 ppm: 100 ppm
Accuracy Maximum: ±20% of actual value
Calibration Points: 2
Accessories Included:
150 & 2000 ppm Standard Solutions (14 mL each)
  • Sampling Sheet B (5 pcs)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals
  • Storage Case
 
Sodium Ion
Model: Na-11
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 mL (0.05 mL with Sampling Sheet B)
Measurement Range: 2 to 9900 ppm (mg/L)
(0.1 to 430 mmol/L)
Resolution: 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm 
1000 to 9900 ppm: 100 ppm
Accuracy Maximum: ±10% of actual value
Calibration Points: 2
Accessories Included:
150 & 2000 ppm Standard Solutions (14 mL each)
  • Sampling Sheet B (5 pcs)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals
  • Storage Case
 
Nitrate Ion
Model: NO3-11
Measurement Principle: Ion Selective Electrode
Minimum Sample Volume: 0.3 mL (0.05 mL with Sampling Sheet B)
Measurement Range: NO3-: 6 to 9900 ppm (mg/L)
(0.1 to 160 mmol/L)
NO3-N: 1.4 to 2200 ppm (mg/L)
Resolution: 0 to 99 ppm: 1 ppm
100 to 990 ppm: 10 ppm 
1000 to 9900 ppm: 100 ppm
Accuracy Maximum: ±10% of actual value
Calibration Points: 2
Accessories Included:
150 & 2000 ppm Standard Solutions (14 mL each)
  • Sampling Sheet B (5 pcs)
  • CR2032 Batteries (2)
  • Dropper
  • Instruction & Quick Manuals
  • Storage Case