HRA SERIES
The HRA series, built-in with our highly advance stainless steel plate heat exchanger, deters refrigeration bad with great efficiency of heat-exchanging. Saving in electrical power and convenient in maintenance are its unique feature.
Features
Stainless steel brazed plate heat exchanger
• No rust water and corrosion
• One-Pass structure = Heat exchanger and reheater
Automatically adapts to system needs
Fully automatic operation saves money
Every unit cones pre-assembled with quality components
User friendly controller
• Power-on LED, Compessor-on LED, On / Off rocker switch and dew point bar graph LED display
Reliable timed electric drain with push-to-test button on the front panel
Electro-galvanized steel cabinet with two part epoxy coating
• Providing long term corrosion resistance
Environmentally friendly R-407C refrigerant
No loss than valve (Optional)
System Control Monitor II (SCM II—Optional)
LCD main window displays
• Dyer run, autodrain valve on, Fan motor on, Alarm
LCD monitor displays
• Inlet, Ambient / Cooling water, Chiller inlet & discharge refrigerant temperatures, Discharger refrigerant temperatures.
Membrane touch panel
Programmable timer drain settings
How it works
Saturated incoming compressed air is quickly chilled in the air-to-air heat exchanger by the cold compressed air as it exits the air-to-refrigerant (evaporator). Here, the cold dry air is reheated to prevent pipeline sweating and reduce compressor energy before exiting the dryer. In the evaporator, the air temperature is reduced to that of the cold refrigerant. A moisture separator lowers the velocity and mechanically separates the condensate from the air stream. An automatic drain removes the condensate. The air-to-air heat exchanger re-heats the air and clean, dry compressed air exits the dryer.
Model | Flow Capacity (Nm3/min) |
Unit (kW) | Power Supply |
Inlet / Outlet Connection (PT) |
Weight (kg) |
Dimension(mm) | Refrigerants | ||
H | W | D | |||||||
HRA 24.0 | 24.06 | 4.5 | 380 – 420 V 3PH 50Hz |
3” | 385 | 1470 | 750 | 1400 | R-407C |
HRA 31.4 | 31.48 | 6.1 | 4” | 400 | 1470 | 750 | 1400 | ||
HRA 37.5 | 37.52 | 7.6 | 4” | 440 | 1470 | 750 | 1400 | ||
HRA 45.1 | 45.10 | 8.6 | 4” | 850 | 1582 | 860 | 1600 | ||
HRA 60.0 | 60.00 | 9.5 | 6” | 1000 | 1628 | 1050 | 1800 | ||
HRA 75.0 | 75.00 | 10.3 | 6” | 1050 | 1628 | 1050 | 1800 | ||
HRA 90.1 | 90.10 | 11.8 | 6” | 1100 | 1628 | 1050 | 1800 | ||
HRA 120.0 | 120.00 | 15.1 | 8” | 2000 | 2320 | 1500 | 2850 | ||
HRA 150.1 | 150.10 | 20.8 | 8” | 2300 | 2320 | 1500 | 2850 | ||
HRA 180.3 | 180.30 | 25.7 | 8” | 2500 | 2320 | 1500 | 2850 | ||
HRA 240.1 | 240.10 | 38.5 | 8” | 3500 | 2320 | 1500 | 3800 | ||
HRA 300.3 | 300.30 | 46.6 | 10” | 4800 | 2400 | 1600 | 4800 | ||
HRA 360.3 | 360.30 | 52.7 | 10” | 5000 | 2400 | 1600 | 4800 |
barG | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
Factor | 0.87 | 0.92 | 0.96 | 1.00 | 1.03 | 1.07 | 1.10 | 1.12 | 1.14 |
°C | 30 | 35 | 40 | 45 | 49 |
Factor | 1.22 | 1.00 | 0.84 | 0.71 | 0.60 |
°C | 20 | 25 | 30 | 35 | 40 | 43 |
Factor | 1.06 | 1.00 | 0.92 | 0.85 | 0.78 | 0.72 |
Hz | 50 | 60 |
Factor | 1.00 | 1.20 |