• Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR. • 3400 counts with bargraph display. • Pocket size and heavy duty design. How to put test lead in. DC V 340mV/3.4/34/340/600V (Input Impedance: 10MΩ) ±1.5%rdg±4dgt AC V 3.4/34/340/600V (Input Impedance: 10MΩ) ±1.5%rdg±5dgt [50 - 400Hz] DC A 60A ±2%rdg±5dgt AC A 60A ±2%rdg±5dgt (50/60Hz) Ω 340Ω/3.4/34/340kΩ/3.4/34MΩ ±1%rdg±3dgt (0 - 340kΩ) ±5%rdg±5dgt (3.4MΩ) ±15%rdg±5dgt (34MΩ) Continuity buzzer Buzzer sounds below 30±10Ω (Continuity buzzer works on 340Ω range only) Frequency (AC A) 3.4/10kHz ±0.1%rdg±1dgt (AC V) 3.4/34/300kHz ±0.1%rdg±1dgt (Input sensitivity Current: more than 15A, Voltage: more than 30V) Conductor size Ø6mm max. Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2 IEC 61010-031, IEC 61010-2-032, IEC 61326-1 Power source R03 (DC 1.5V) × 2 * Continuous measuring time: approx. 45 hours (Auto power save: approx. 10 minutes) Dimensions 128(L) × 87(W) × 24(D)mm Weight 210g approx. Included Accessories R03 (DC 1.5V) × 2, Instruction Manual Optional Accessories 9107 (Carrying case [Soft])