HIOKI IR5051 HIGH VOLTAGE INSULATION TESTER

HIOKI IR5051 HIGH VOLTAGE INSULATION TESTER

分类: INSULATION TESTER 当前有货
可在官方网站购买
欲了解更多详情,请游览我们的官方网站 accutac.com.my

Specifications
  • HIOKI HIGH VOLTAGE INSULATION TESTER IR5051: Measure Solar PV System Insulation Resistance Safely and Accurately While Generating. Maximum 5kV Test Voltage - Up to 10 TΩ of Insulation Resistance Testing.
详情

HIOKI IR5051 HIGH VOLTAGE INSULATION TESTER
Measure Solar PV System Insulation Resistance Safely and Accurately While Generating.
Maximum 5kV Test Voltage - Up to 10 TΩ of Insulation Resistance Testing.

The IR5051 is a compact, lightweight, high-voltage insulation resistance tester capable of outputting up to 5 kV. Its unique measurement technology enables stable measurements of up to 10 TΩ. In addition, the IR5051 is capable of testing the insulation resistance of solar PV systems during power generation, and has a CAT III 2000 V safety rating to allow testing of 2000 V PV systems.

Dedicated Measurement Function
In addition to a normal insulation resistance measurement mode, the IR5051 also features a specialized mode for measuring PV insulation resistance.
Flexible Voltage Range
Effectively measures 1500 V solar PV systems and is prepared to accommodate systems up to 2000 V as technology advances.
Standards Compliance
Complies with IEC 62446-1 for Category 1 and Category 2 tests, ensuring robust safety and performance

Key Features

Basic specifications

Accuracy guaranteed: 1 year
Measurement parameters • Insulation resistance
• PV insulation resistance
• Leakage current
• Voltage
• Capacitance (DD function)
Max. rated voltage to terminals 1000 V AC, 2000 V DC
Max. rated voltage to ground 1000 V (CAT IV), 600 V (CAT III)
Operating temperature and humidity range -20°C to 50 °C (*1) (no condensation)
Storage temperature and humidity range -25°C to 65°C (-13°F to 149°F), less than 80% RH (no condensation)
Dustproof/waterproof IP40 (with protector attached, excluding terminals)
IP65 (CARRYING CASE C0212)
Standards EN61010 (safety), EN61326 (EMC), IEC 61557-1, IEC 61557-2 (Insulation resistance tester)
Power supply • LR6 (AA) alkaline battery × 8
• HR6 (AA) nickel-metal hydride (NiMH) rechargeable battery × 8
Continuous operating time (*2) Approx. 5 hours without Z3210 installed; approx. 4 hours with Z3210 installed and using wireless communication
Dimensions and weight 195 mm (7.68 in.) W × 254 mm (10 in.) H × 89 mm (3.50 in.) D, 1.7 kg (59.97 oz.) (including batteries)
Included accessories Test lead L9850-01 ×1, Test lead L9850-02 ×1, Test lead L9850-03 ×1, Alligator clip L9851-01 ×1, Alligator clip L9851-02 ×1, Alligator clip L9851-03 ×1, Test pin set L9852 ×1, Carrying Case C0212 ×1, LR6 Alkaline battery ×8, Instruction manual ×1, Operating precautions ×1, Wireless adapter Z3210(IR5051-90 only)

Functions

Insulation diagnosis PI, DAR, DD, SV, Ramp, Timer (*3)
Others Battery charge indicator, live circuit indicator, automatic power save, automatic discharge, backlight, buzzer, manual recording, logging recording, temperature and humidity input, elapsed time display, clock, filter, hardware filter, data-hold, system reset, USB communication (only when DT4900-01 is installed), wireless communication (only when Z3210 is installed), comparator, resistance gauge display, switching of insulation diagnosis function, breakdown cut-off, negative voltage notification

PV insulation resistance

Test voltage range DC 250 V to 2.00 kV
Test voltage presets 500 V, 1 kV, 1.5 kV
User-set test voltage 250 V to 1 kV: in 10 V increments; 1 kV to 2 kV: in 25 V increments
Test voltage preset 500 V 1000 V 1500 V
Guaranteed accuracy range (1) 0.00 MΩ to 5.00 GΩ ±5% rdg ±5 dgt 0.00 MΩ to 10.00 GΩ ±5% rdg ±5 dgt 0.00 MΩ to 20.0 GΩ ±5% rdg ±5 dgt
Guaranteed accuracy range (2) 5.01 GΩ to 100 GΩ ±20% rdg 10.1 GΩ to 100 GΩ ±20% rdg 20.1 GΩ to 100 GΩ ±20% rdg
Rated current [Test voltage] / [20 MΩ]
Open-circuit voltage From 0% to 10% of test voltage
Short-circuit current 2 mA or less
Possible number of measurements 1000 times or more on one set of fully-charged batteries

Insulation resistance measurement

Test voltage range DC 250 V to 5.20 kV DC
User-set test voltage 250 V to 1 kV: in 10 V increments; 1 kV to 5 kV: in 25 V increments
Test voltage preset 250 V 500 V 1000 V 2500 V 5000 V
Guaranteed accuracy range (1) 0.00 MΩ02.50 GΩ ±5% rdg ±5 dgt 0.00 MΩ05.00 GΩ ±5% rdg ±5 dgt 0.00 MΩ010.0 GΩ ±5% rdg ±5 dgt 0.00 MΩ025.0 GΩ ±5% rdg ±5 dgt 0.00 MΩ050.0 GΩ ±5% rdg ±5 dgt
Guaranteed accuracy range (2) 2.51 GΩ0500 GΩ ±20% rdg 5.01 GΩ01.00 TΩ ±20% rdg 10.1 GΩ02.00 TΩ ±20% rdg 25.1 GΩ05.00 TΩ ±20% rdg 50.1 GΩ010.00 TΩ ±20% rdg
Rated current 1 mA to 1.2 mA
Short-circuit current 2 mA or less
Possible number of measurements 200 times or more on one set of fully-charged batteries

Leakage current measurement

Measurement range (auto) 10 nA 100 nA 1000 nA 10 μA 100 μA 1 mA
Display range 0.00 nA to 9.99 nA 9.0 nA to 99.9 nA 90 nA to 999 nA 0.90 μA to 9.99 μA 9.0 μA to 99.9 μA 90 μA to 999 μA (*4)
0.90 mA to 3.00 mA (*5)
Resolution 0.01 nA 0.1 nA 1 nA 0.01 μA 0.1 μA *4: 1 μA
*5: 0.01 mA

Voltage measurement

Guaranteed accuracy range 30 V to 1,000 V AC (45 Hz to 65 Hz), ±10 V to ±2,000 V DC
Accuracy ±3% rdg. ±3 dgt.
Input resistance 500 kΩ or more (DC, 45 Hz to 65 Hz)
Overload protection 1100 V AC (1 min., between +/- terminals)
2200 V DC (1 min., between +/- terminals)

Capacitance measurement

Capacitance is automatically measured after insulation resistance measurement is over (not measured if output voltage is 250 V or less)
Accuracy ±10% rdg. ±5 nF (guaranteed accuracy range: 10.0 nF to 25.0 µF)
Measurement range 100 nF 1000 nF 10 μF
Display range 0.0 nF to 99.9 nF 100 nF to 999 nF 1.00 μF to 9.99 μF (*6)
10.0 μF to 25.0 μF
(*7)
Resolution 0.1 nF 1 nF *6: 0.01 μF
*7: 0.1 μF

 



 

更多 Accutac Sdn Bhd 相关资料
Accutac Sdn Bhd
Accutac Sdn Bhd Thermal Imager Supplier Penang, Data Logger, LCR Meter Supply Malaysia, Power Quality Meter, Precision Measuring Instruments Supplies Bayan Lepas ~ Accutac Sdn Bhd