Model | 8902 |
Wind Speed Range | 0.6~32 m/s |
Wind Speed Accuracy | ±(2% of reading+0.2 m/s) |
Air Temperature Range | -20~60℃ |
Air Temperature Resolution | 0.1℃, 0.1! |
Air Temperature Accuracy | ±0.6℃ |
Air RH% Range | 0%~100%RH |
Air RH% Resolution | 0.1%RH |
Air RH% Accuracy | ±3%RH (at 25℃. 10~90%RH, others ±5%RH) |
Temperature Response Time | 60 seconds (typical) |
Air RH% Response Time | 60 seconds (typical) |
LCD Update | Every second |
Wet Bulb Temp. Display | -22~70℃ |
Dew Point Temp. Display | -68~70℃ |
Air Volume Display | 0~99999 m3/minute |
Air Volume Resolution | 0.1 (0~9999.9) or 1 (10000~99999) |
LCD Size | 44(L) * 26(W) mm |
Operating Temperature | 0~50℃ |
Operating RH% | Humidity <80% |
Storage Temperature | -10~50℃ |
Storage RH% | Humidity <90% |
Size | Meter: 175(L) * 70(W) * 33(H) mm Vane: 170(L) * 77(W) * 40(H) mm |
Weight | ~170g |
Battery | AAA*4 PCS or 9V DC Adaptor |
Optional Accessory | Replacement Vane Probe / Software Kit |
Standard Package | Meter, Vane Probe, Batteries, Manual, Hard Carry Case |