General Specifications | |
Sensing distance | 80…2000mm |
Adjustment range | 120…2000mm |
Unusable area | 0…80mm |
Standard target plate | 100mm×100mm |
Transducer frequency | About 112kHz |
Response delay | About 195ms |
Indicators/Operating means | |
LED blue | Power on |
LED yellow |
indication of the switching state Flashing:program function object detected |
LED red |
permanently red: Error Red,flashing:program function,object not detected |
Electrical specifications | |
Operating voltage U B | 10…30VDC,ripple10%ss |
Power consumption P 0 | ≤20mA |
Input | |
Input type |
1 TEACH-IN input Operating distance A1:-U B …+1V,operating distanceA2:+6… + U B Input impedance:>4.7KΩ TEACH-IN programmable pulse :≥1S |
Output | |
Output type | 1 switch output E5,PNP NO/NC,programmable |
Rated operational current | 200mA,short-circuit/overload protected |
Default setting | Switching point A1:70mm Switching point A2: 800mm |
Voltage drop | ≤ 3V |
Repeat accuracy | ≤ 1% |
Switching frequency f | ≤ 4HZ |
Range hysteresis H | 1% of the set operating distance |
Temperature influence | ± 1.5% of full-scale value |
Ambient conditions | |
Ambient temperature | -25…70℃(248...343K) |
Storage temperature | -40…85℃(233...358K) |
Mechanical specifications | |
Protection grade | IP67 |
Connection | V1 connector(M12×1),4-pin |
Material Housing | brass,nickel-plated |
Transducer |
epoxy resin/hollow glass sphere mixture; Polyurethane foam |
Weight | 25g |