The HI11102 HALO is a Bluetooth® Smart (Bluetooth 4.0) pH and temperature electrode. This electrode is composed of a glass body and spheric, general purpose glass sensing bulb. The double junction design ensures that the gel electrolyte is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell, resisting clogging and any potential precipitation at the junction. All readings are transmitted directly to the HI2202 edgeblu or a compatible Apple or Android device running the Hanna Lab App.
Easily connect to the Hanna Lab App at the press of a button via Bluetooth wireless technology.
Visible from a distance, the LED “halo” light flashes to indicate the status of the probe.
The HALOs CR2032 lithium ion battery is easily replaceable and lasts for approximately 500 hours.
The HI11102 HALO is a revolutionary pH electrode that incorporates Bluetooth Smart (Bluetooth 4.0) wireless technology with an application specific design. This electrode has many features that makes it ideal for laboratory use. These features include general purpose (GP) glass, spheric bulb, integrated temperature sensor, glass body, and double reference junction with silver-free gel electrolyte.
General Purpose (GP) glass, as the name implies, is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25°C and is suited for measuring pH of samples that are at ambient temperatures. The HI11102 is suitable to use with samples that measure from -5 to 80°C (23 to 176°F).
The spheric bulb is for general purpose use within laboratory environments and applications that measure aqueous solutions due to its large surface area. Other tip shapes include conic for penetration and flat tip for surface measurements.
HI11102 features a built-in thermistor temperature sensor that is in the tip of the indicating pH electrode. A thermistor temperature sensor provides for a high accuracy temperature reading and should be as close as possible to the indicating pH electrode in order to compensate for the effect that temperature has on the membrane potential as predicted by the Nernst equation. By having an accurate reading it is possible to provide a temperature compensated reading.
The glass body of the HI11102 is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easy to clean. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent, so the faster thermal equilibrium is reached, the steadier the reference potential.
The HI11102 is a double junction design. pH electrodes are available as single junction or double junction. See below for a complete description of the differences. The junction also known as a salt bridge is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction allows the gel electrolyte to flow at a rate of 15-20 μL/hour.
Conventional electrodes are normally single junction. As depicted by the figure above, these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions, such as high pressure, high temperature, highly acidic or alkaline solutions, the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked, the reference electrode can become contaminated, leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample, some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.
Hanna’s double junction system, as the name implies, has two junctions, only one of which is in contact with the sample as shown in the figure. Under adverse conditions, the same tendency of sample ingress is evident. However, as the reference electrode system is separated physically from the intermediate electrolyte area, the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free.” Since there is no silver present, there is no precipitate that can form to clog the junction.
HALO pH electrodes can connect with HI2202 edgeblu meter or a compatible Apple or Android device running the Hanna Lab App.
The Hanna Lab App turns a compatible Apple or Android device into a full-featured pH meter when used with the Hanna HALO pH probe with Bluetooth Smart technology. Functions include calibration, measurement, data logging, graphing and data sharing. Measurement and logging of pH and temperature at one second intervals start as soon as the probe is connected. Measurements can be displayed alone on the display, with tabulated data, or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.
The Hanna Lab App incorporates a probe calibration using up to five pH buffers that are automatically recognized and temperature corrected to 25.0ºC during calibration.
Display of pH and temperature updated every second. Readings are automatically saved to a history file every hour, limited only by the available memory on the device.
Measurement can be displayed with tabulated data or a graph on the display. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing.
Connecting the HALO probe to the Hanna Lab App is simple. Tap the Bluetooth icon in the top-right corner to view all available HALO probes then press the button on your HALO probe. Select the newly discovered HALO probe from the list of available probes. If a previously associated probe is in discovery mode when the app is opened it will connect to that probe automatically.
Displays date and time of current calibration, probe offset, and average slope, along with calibrated buffers, mV values, temperature and slopes between each buffer.
The Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.
Saved log files may be annotated with measurement-specific information. Data can easily be shared via email in CSV format.
Demo probe mode helps you explore features of the Hanna Lab App. General app information, General HALO information, pH tutorial, maintenance tutorial, and contact information are available in help.
HALO pH electrodes are compatible with HI2202 edgeblu meter and the following devices:
Android
Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later.
iOS
iPad (3rd generation or newer)
iPhone (4S or newer)
iPod Touch (5th generation or newer)
Information about which products have Bluetooth Smart Technology (4.0), also known as low energy (LE), can be found here.
SKU | HI11102 |
---|---|
Product Name | HALO Glass Body Gel Filled pH Electrode with Bluetooth® - HI11102 |
Quote Required | Yes |
Measurement Range | pH |
Reference Cell Type | double, Ag/AgCl |
Junction Type/Flow Rate | ceramic, single |
Type of Electrolyte | gel |
Body Material | glass |
Tip / Shape | spheric |
Matching Pin | no |
Max. Pressure | 0.1 bar |
Temperature Operating Range | -5 to 80°C (23 to 176°F) |
Body Length/Overall Length | 120 mm / 183 mm |
Temperature Sensor | yes |
Outer Diameter | 12 mm |
Connector Type | Bluetooth Smart (Bluetooth 4.0), 10 m (33') range |
Battery Type/Life | CR2032 3V lithium ion / approximately 500 hours |
Amplifier | yes |
Recommended Use | laboratory general purpose |
Notes | Environment |
Range | -2.000 to 16.000 pH / ±800 mV / -20.0 to 120.0 ºC *(will be reduced to actual probe/sensor limits) |
Resolution | 0.1, 0.01, 0.001 pH / 1, 0.1 mV |
Accuracy (@25ºC/77ºF) | ±0.005 pH / ±0.3 mV |
Calibration Points | Up to five points with seven standard buffers |
Calibration Buffers | 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH |
Temperature Compensation | Automatic from -5.0 to 100.0 ºC / 23.0 to 212.0 ºF *(will be reduced to actual probe/sensor limits) |
Compatibility/System Requirements | Android |
Download Information | Hanna Lab App is available free from the Play Store or App Store |
Ordering Information | HI11102 (HALO) is supplied with storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, battery, quality certificate and instruction sheet. |