*HI38023 Total Chlorine Extended Range Test Kit

*HI38023 Total Chlorine Extended Range Test Kit

Kategori: Chemical Test Kits Tersedia (Jml:1)
Bisa dibeli di situs resmi
RM 304.00 Untuk informasi lebih lanjut, kunjungi situs resmi kami di hannamalaysia.com

Deskripsi

The HI38023 is a chemical test kit that measures total chlorine by iodometric titration. The HI38023 is supplied complete with all of the reagents and equipment necessary to perform approximately 100 tests.


  • Pre-made reagents for ease of use
  • All reagents marked with expiration date and lot number for traceability
  • Manual titration with starch indicator

Details

The HI38023 is a titration-based chemical test kit that determines the total chlorine concentration within a 10 to 200 mg/L (ppm) range. The HI38023 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform approximately 100 tests. An iodometric titration method is used. The water sample is treated with potassium iodide and strongly acidified with acid. The amount of iodide generated is equivalent to the concentration of chlorine in the sample; the concentration of iodine is calculated by titration with thiosulfate ions that reduce iodine ions back to iodide ions.

Features at-a-glance

  • Complete setup

    • All required materials are included with the test kit, such as the glass vials, plastic pipette, reagent packets, and Checker® disc.

  • High resolution

    • Readings from 10 to 200 mg/L are determined to 10 mg/L resolution.

  • Replacement reagents available

    • There is no need to buy a new kit when reagents are exhausted. The HI38023-100 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 1 (30 mL) dropper bottle potassium iodide solution, 100 packets sulfamic reagent, 1 (25 mL) dropper bottle starch indicator, and 100 mL bottle thiosulfate reagent.


 

Significance of Use

The chlorination of water supplies and polluted waters is used mainly to destroy or deactivate disease-producing microorganisms. Chlorine also serves to improve the quality of drinking waters, as it reacts with ammonia, iron, manganese, sulfide, and some organic substances. Nevertheless, high amounts of chlorine will produce adverse effects like the formation of compounds which are potentially carcinogenic (e.g. chloroform) or harmful to aquatic life (e.g. chloramines). It remains essential to control the amount of added chlorine in order to fulfill the primary purpose of disinfecting while also minimizing any adverse effects.
 

Specifications

 

Range 10 to 200 mg/L (ppm)
Resolution 10 mg/L (ppm)
Method iodometric
Number of Tests 100
CTK Type Titration
Weight 547 g
Ordering Information HI38023 test kit comes with 30 mL potassium iodide solution, sulfamic reagent (100 packets), 25 mL starch indicator, 100 mL thiosulfate reagent, 50 mL calibrated vessel, 1 mL syringe with tip, 1 mL plastic pipette, and spoon.