Deskripsi
View old post here
The high-temperature tube furnaces are available in either horizontal (type RHTH) or vertical (type RHTV) designs. High-quality insulation materials made of vacuum-formed fiber plates enable energy-saving operation and a fast heating time due to low heat storage and heat conductivity. By using different gas supply systems, operations can be performed under non-flammable or flammable protective or reactive gases or under vacuum.
-
Tmax 1600 °C, 1700 °C, or 1800 °C
-
MoSi2 heating elements, mounted vertically for easy replacement
-
Insulation with vacuum-formed ceramic fiber plates
-
Only fiber materials are used which are not classified as carcinogenic according to TRGS 905, class 1 or 2
-
Rectangular outer housing with slots for convection cooling
-
Tube furnaces RHTV with frame for vertical operation
-
Dual shell housing made of sheets of textured stainless steel
-
Ceramic working tube made of material C 799 incl. fiber plugs for operation under air
-
Type B thermocouple
-
Power unit with low-voltage transformer and thyristor
-
Over-temperature limiter with adjustable cutout temperature for thermal protection class 2 in accordance with EN 60519-2 as temperature limiter to protect the furnace and load and with selectable maximum temperature gradient as tube protection
-
Switchgear and control unit separate from furnace in separate floor standing cabinet
-
Defined application within the constraints of the operating instructions
-
NTLog Basic for Nabertherm controller: recording of process data with USB-flash drive
Additional equipment
-
Charge control with temperature measurement in the working tube and in the furnace chamber outside the tube
-
Display of inner tube temperature with additional thermocouple
-
Gas tight flanges for protective gas and vacuum operation
-
Manual or automatic gas supply system
-
Three-zone control for optimization of temperature uniformity (only tube furnaces RHTH)
-
Check valve at gas outlet avoids intrusion of false air
-
Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Model
Horizontal design |
Tmax °C |
Outer dimensions in mm |
Max. outer tube Ø/mm |
Heated length mm |
Length constant temperature ±5K |
Tube length in mm |
Connected load kW |
Electrical connection |
Weight in kg |
W |
D |
H |
RHTH 50/150/.. |
1600 or |
470 |
480 |
640 |
50 |
150 |
50 |
380 |
5.4 |
3-phase |
70 |
RHTH 80/300/.. |
1700 or |
620 |
550 |
640 |
80 |
300 |
100 |
530 |
9.0 |
3-phase |
90 |
RHTH 120/600/.. |
1800 |
920 |
550 |
640 |
120 |
600 |
200 |
830 |
14.4 |
3-phase |
110 |
Model
Vertical design |
Tmax °C |
Outer dimensions in mm |
Max. outer tube Ø/mm |
Heated length mm |
Length constant temperature ±5K |
Tube length in mm |
Connected load kW |
Electrical connection |
Weight in kg |
W |
D |
H |
RHTV 50/150/.. |
1600 or |
500 |
650 |
510 |
50 |
150 |
30 |
380 |
5.4 |
3-phase |
70 |
RHTV 80/300/.. |
1700 or |
580 |
650 |
660 |
80 |
300 |
80 |
530 |
10.3 |
3-phase |
90 |
RHTV 120/600/.. |
1800 |
580 |
650 |
960 |
120 |
600 |
170 |
830 |
19.0 |
3-phase |
110 |
Lihat detail lebih lanjut tentang Obsnap Instruments Sdn Bhd