PULSAR MEASUREMENT ULTRA 4

PULSAR MEASUREMENT ULTRA 4

Kategori: CONTROLLER Tersedia
Untuk informasi lebih lanjut, kunjungi situs resmi kami di hsa-asia.com

Deskripsi

Ultra 4

The Ultra 4 is a fully functional advanced controller for level, flow, volume, and pump control. MCERTS Class 1 certified, it offers open channel flow measurement for stormwater overflows and event duration monitoring.

The multifunctional display offers the ability to be able to view trend graphs on-screen and get a glance at how levels have changed over time. When combined with the dB3 with double sun shields, the Ultra 4 achieves MCERTS Class 1 certification, with 0.036% combined accuracy, meaning the system has undergone rigorous testing and has achieved a high standard in every single one. This means that wastewater processes across the world can achieve a common standard on their flow applications, providing real-time data on flow into storm tanks, influent flow, and event duration monitoring. 

In addition to the Ultra 4's open channel flow features, the unit offers sophisticated level control, includes built-in volume calculations based on standard tank shapes, and advanced pump control functions.

The unit can be wall or fascia mounted, includes Profibus digital communication options, and the convenience of the onboard Micro SD card allows for extended data logging.

Features 

Technical Specifications 

General Specifications
Spec: Description:
Weight: 700g (1.5 lbs) 
Dimensions:  Wall Mount: 150 mm x 130 mm x 63.5 mm (5.9 in x 5.1 in x 2.5 in) 
Fascia Mount: 160 mm x 180 mm x 63 mm (6.3 in x 7.07 in x 2.5 in)
Enclosure Material/Description:  Polycarbonate, flame resistant to UL94-V0
Cable Entry Detail:  3 x M20 glands
Transducer Cable Extensions: 3-core Screened
IP Rating: IP67/NEMA 4X for wall mount IP64 for fascia mount
Operating Temperature (Electronics):  -20 ºC to +45 ºC (-4 ºF to +113 ºF)
Accuracy: 0.25% of the measured range or 6mm (whichever is greater) +/- 2 mm (0.079 in) for dBR16 mmWAVE RADAR
Resolution: 0.1% of the measured range or 2 mm (0.079 in); whichever is greater
Analog Output:  Isolated floating output (to 150 V) of 4-20mA or 0-20mA into 1 kΩ; user-programmable and adjustable
Volt Free Contacts, Number, and Rating:  3 x SPCO isolated relays, rated at 5 A at 250 V AC and 1 Solid-state SPNO isolated relay, rated 30 V at 100 mA, suitable for pulse counter applications

 

Lihat detail lebih lanjut tentang HSA ASIA SDN BHD
HSA ASIA SDN BHD
HSA ASIA SDN BHD Measuring Instruments Selangor | Flow Meter Supply Kuala Lumpur (KL) | Water Analytical Instruments Supplier Malaysia ~ HSA ASIA SDN BHD