Deskripsi
DriveScan
Continuous Remote Monitoring for Medium Voltage Drives.
Overview
DriveScan is the premiere system and service for real-time remote monitoring of medium-voltage (MV) drives. It continuously captures critical drive and facility health indicators for faster detection and recovery of adverse events. DriveScan’s comprehensive and modular sensor suite is integrated into each drive enabling safe detection of intermittent and evolving faults.
Its powerful cloud-based software and intelligent fleet management dashboard help identify potential problems early, allowing a proactive vs reactive response. Its dashboard synthesizes data across all drives to display an intuitive health overview and enables single-drive drill-down for detailed troubleshooting.
Using DriveScan will:
Increase drive uptime through data-driven failure prediction
Reduce operation and service costs through remote analytics and avoided service calls
Features
• Monitored subsystems
-
Input & Output Current, Voltage
-
Power Module DC bus
-
Low voltage power supplies
-
Internal temperature and humidity
• Fully synchronized data and reports across all channels provide event sequences, root cause analysis, and trend tracking
• Single drive dashboard drill-down
• Traffic-light indicators and alarms to convey issue type and severity
• Secure cloud-based hosting and data storage
• Support from global MV VFD experts EMA
Application
• Compatibility: Most MV voltage-source drives with 6-15 power modules
• Use cases:
-
Remote operational oversight
-
Fault avoidance, detection, isolation, and accelerated recovery
-
Energy management & metering
-
Facility monitoring
• Typical applications sectors
-
Pipeline, Water Treatment, Industrial
Architecture Diagram
A detailed view of Medium Voltage Drive health
DriveScan modular sensors are fully integrated with the drives, allowing intermittent and evolving faults to be safely detected.
Technical Specifications
LINE MONITORING |
Drive Input |
2000 to 12,470 Vac. 50/60Hz. Measured via existing PT’s or Voltage Dividers. Typ. Accuracy ±0.01% |
Power Quality |
Voltage Magnitude, Unbalance, THD, Harmonics to 50th rank (IEC 61000-4-30 Class A Ed 3) |
Current Measurements |
Unbalance, TDD (via CT’s. Typ. Magnitude Accuracy ± 1%.) |
Power |
VA, kW, VAR, 4 quarant PF |
Power Quality Disturbances |
Sags/Swells/Interruptions, RVC, HF impulses (4MHz sampling) |
MOTOR MONITORING |
Drive Input |
Voltage and Current average, Waveform |
DC BUS MONITORING |
Sensing Isolation |
Proprietary optically isolated MV sensors |
Magnitude and ripple |
DC bus voltage: 400 to 2000 Vdc |
LOW VOLTAGE POWER SUPPLY MONITORING |
Number of channels |
8 channels, 0 to 60 Vdc |
Control power supply monitoring |
Typ. 5 Vdc, +/-15 Vdc, 24 Vdc |
ENVIRONMENTAL MONITORING |
Connection |
ENV2 probe connected via USB. Functional electrical isolation. |
Sampling rates |
1 sample per second typical for temperature, humidity, barometric pressure.8, 16, 32 samples per second, user selected for acceleration recording. |
Temperature |
-20 to 80 °C (-4 to 176 °F) |
Humidity |
0 % to 100 %RH (useful range: 20 % to 80 %RH) |
Barometric Pressure |
Indicative measurements, resolution better than 0.001 hPa |
LIMITS |
Ambient Temperature |
0 to 40 °C (32 to 104 °F) |
Humidity |
0 to 95% RH |
CERTIFICATIONS |
IEC 61010; IEC 61000-4-30; IEC 61000-4-7; IEC 61000-4-15; TUV Type-B pending Drivescan components are tested by Underwriters Laboratory (UL) to meet the requirements of IEC 61010-2-30 MVM-1000 is tested at 1000 VDC and MVM-2000 is tested at 1500 VDC per UL and IEC limits |
Powerside does not represent or warrant that drive or installation certifications will be unaffected by DriveScan installation |
Drive Scan / Energy Values / Powerside / Electric Parameters / Remote Monitoring / Medium Voltage Drives / Powerside / Energy Monitoring. DriveScan Portable from Saturn Pyro is the best available in Malaysia. High performance and cost effective Power Energy Meter which is suitable for Low Voltage installations, in both 3 and 4-wire three-phase circuits, two-phase circuits with or without neutral, single-phase circuits or ARON connections.. Available in Penang, KL, Selangor, Johor, Sabah, Sarawak & anywhere in Malaysia & Singapore.
Saturn Pyro provides reliable engineering services such Electrical Safety Survey, Power System Studies (Short Circuit, Load Flow & Protection Discrimination on ETAP), Arc Flash Assessment & Labeling, Design Of Earthing & Lightning Protection, Measurement Of Touch & Step potentials, Power Quality Management, Energy Audit and Data Center Performance Assessment. We also provides Electrical Safety Survey such as Inspection of an electrical installation, Identification of risk (electrical hazards), Review of documentation, operations & maintenance procedures, contingency planning, Generation of report in details of risk potentials and plan for mitigation, Closing report post implementationas. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.
Imbasan Pemacu / Nilai Tenaga / Sisi Kuasa / Parameter Elektrik / Pemantauan Jauh / Pemacu Voltan Sederhana / Sisi Kuasa / Pemantauan Tenaga. DriveScan Portable dari Saturn Pyro adalah yang terbaik yang terdapat di Malaysia. Meter Tenaga Kuasa berprestasi tinggi dan kos efektif yang sesuai untuk pemasangan Voltan Rendah, dalam kedua-dua litar tiga fasa 3 dan 4 wayar, litar dua fasa dengan atau tanpa neutral, litar fasa tunggal atau sambungan ARON.. Tersedia di Pulau Pinang, KL, Selangor, Johor, Sabah, Sarawak & di mana-mana sahaja di Malaysia & Singapura.
Saturn Pyro menyediakan perkhidmatan kejuruteraan yang boleh dipercayai seperti Tinjauan Keselamatan Elektrik, Kajian Sistem Kuasa (Litar Pintas, Diskriminasi Aliran Beban & Perlindungan pada ETAP), Penilaian & Pelabelan Denyar Arka, Reka Bentuk Pembumian & Perlindungan Kilat, Pengukuran potensi Sentuhan & Langkah, Pengurusan Kualiti Kuasa , Audit Tenaga dan Penilaian Prestasi Pusat Data. Kami juga menyediakan Tinjauan Keselamatan Elektrik seperti Pemeriksaan pemasangan elektrik, Pengenalpastian risiko (bahaya elektrik), Semakan dokumentasi, prosedur operasi & penyelenggaraan, perancangan kontingensi, Penjanaan laporan dalam butiran potensi risiko dan rancangan untuk mitigasi, Pos laporan penutup perlaksanaan. Available in Pulau Pinang, Johor, Kuala Lumpur (KL), Selangor and anywhere in Malaysia / Singapore / Bangalore / India / Mumbai.