Deskripsi
HIOKI DT4256 Digital Multimeter
Standard DMM that Delivers Top Safety and Reliability - General Purpose Testers with Rich Measurement Functions
OVERVIEW
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4256 is a digital multimeter designed to deliver maximum functionality for use in a wide range of settings.
CAT IV 600 V, CAT III 1000 V
Key Features
- ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
- Measure up to 10 A with direct input
- Dual display lets you check voltage and frequency simultaneously
- Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
- USB communications function supports PC measurements (optional)
- Broad -25°C to 65°C (-13°F to 149°F) operating temperature range
Model No. (Order Code)
DT4256 |
Digital Multimeter, Multi-functional model, with 10 A direct input |
FEATURES
Multifunctional digital multimeter
- DC current 60.00mA / 600.0mA / 6.000A / 10.00A
- Accepts an AC clamp sensor.
- Voltage detection function
Measure output voltage on the secondary sides of inverters by eliminating harmonic components
Accurately measure the fundamental wave alone by eliminating harmonic components with the DMM’s low-pass filter function.
Measurement data can be downloaded to, reviewed on, and saved to a computer.
If you connect the DT4256 to a computer with the optional Communication Package DT4900-01, you can graph data stored in the instrument’s internal memory and display measurement results in real time on the computer. In addition, displayed measured values can be saved (in text format).
*The computer and multimeter are electrically isolated by means of optical communications so that data can be sent without concern for electrical hazards.
True RMS measurement for accurate measurement of even distorted current waveforms
Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement. The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability.
Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mind
All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.
Safe measurement requires use of an instrument that suits the measurement location.
To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.
SPECIFICATIONS
Basic specifications
Accuracy guaranteed: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
DC Voltage range |
600.0 mV to 1000 V, 5 ranges
Basic accuracy: ±0.3 % rdg. ±3 dgt. |
AC Voltage range |
6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz
Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
AUTO AC/DCV |
Yes |
Resistance range |
600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. |
DC Current range |
60.00 mA to 10.00 A, 4 ranges,
Basic accuracy: ±0.9 % rdg. ±3 dgt. |
AC Current range |
600.0 mA to 10.00 A, 3 ranges,
Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt.
(True RMS, crest factor 3, 40 Hz to 1 kHz) |
AC Current range
(use with Clamp on probes) |
10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
Voltage detection
(50/60 Hz) |
Hi: AC40 V to 600 V, Lo: AC80 V to 600 V |
Capacitance range |
1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
Frequency range |
99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current),
Basic accuracy: ±0.1 % rdg. ±1 dgt. |
Continuity check |
Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED),
[OFF]: 245 Ω or more, Response time: 0.5 ms or more |
Diode test |
Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less,
Threshold of forward voltage: 0.15 V to 1.5 V |
Other functions |
Filter function, display value hold, auto hold, MAX/MIN/Average value display, relative value display, auto-power save, USB communication (option) |
Display |
Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
Display refresh rates |
5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s ) |
Power supply |
LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
Dimensions and mass |
84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D,
390 g (13.8 oz) (including batteries and holster) |
Included accessories |
Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 |
Lihat detail lebih lanjut tentang Marktest Technology Sdn Bhd