Thermal shock Immersion Test

Test Method: LV124

Heat chamber:ambient~+150℃, the general test requirement is +70℃

Cool chamber:0℃ salt water

The EV battery performs cold and heat shocks between the hot room and cold room.

Thermal Shock (Without housing)

Test Standard: LV124

 

Operating mode of DUT Operating mode I.a
Lower temperature T(min)
Upper temperature T(max)
Holding time at upper/lower temperature 15min following attainment of complete thermal equilibrium
Transition time ≤10s
Number of cycles 300
Number of DUTs 6 electronice assemblises