Uninterruptible Power Supply (UPS), Rated Capacity: 1-10kVA

Uninterruptible Power Supply (UPS), Rated Capacity: 1-10kVA

Kategori: Electricals Tersedia
Untuk informasi lebih lanjut, kunjungi situs resmi kami di alliance-supplies.com

Deskripsi

Download Uninterruptible Power Supply (UPS), Rated Capacity: 1-10kVA Full Catalog
 
Product Description
The YTR series UPS incorporates advanced digital control technology, three-level topology, and high-frequency power conversion for superior performance. This compact, high-efficiency UPS system is designed with reliability in mind, providing significant energy-saving benefits that help reduce overall operating costs.

Key Features:
• Compact Design, High Performance: Despite its small footprint, the YTR series  delivers outstanding performance and reliability, making it ideal for environments  where space is limited but power protection is critical.
• Integrated Power Solutions: The UPS combines AC voltage regulation, backup  power, and peak surge absorption into one powerful system. It ensures seamless  power protection, even in challenging grid environments.
• Pure, Safe, and Stable Power: Designed to deliver clean and uninterrupted power,  the YTR series safeguards sensitive equipment, ensuring optimal performance and  minimizing the risk of damage from power fluctuation 

Rated capacity: 1-10kVA
Power supply system: Single input and single output
Output voltage: 208/220/230/240Vac
Topological structure: Double conversion on-line

Applications
• Medical Facilities (Clinics, Labs, etc.)
• Data Centers
• Telecommunication / IT Rooms
• Security Systems
• Manufacturing and Industrial Sites
• Educational Institutions
• Healthcare
Index Model YTR1101 YTR1101L YTR1102 YTR1102L YTR1103 YTR1103L YTR1106 YTR1106L YTR1110
input Battery voltage (Vdc) 24 36 48 72 72 96 192 (192~240 can be set) 192 (192~240 can be set) 192 (192~240 can be set)
  Voltage range (Vac) 120~295 120~295 120~295 120~295 120~295 120~295 80ÿ275 80ÿ275 80ÿ275
  Frequency range (Hz) 50/60±10% (adaptive) 50/60±10% (adaptive) 50/60±10% (adaptive) 50/60±10% (adaptive) 50/60±10% (adaptive) 50/60±10% (adaptive) 50/60±10% (adaptive) 50/60±10% (adaptive) 50/60±10% (adaptive)
characteristics Phase Single-phase three-wire Single-phase three-wire Single-phase three-wire Single-phase three-wire Single-phase three-wire Single-phase three-wire Single-phase three-wire Single-phase three-wire Single-phase three-wire
  input power factor >0.99 (full load) >0.99 (full load) >0.99 (full load) >0.99 (full load) >0.99 (full load) >0.99 (full load) >0.99 (full load) >0.99 (full load) >0.99 (full load)
  Input current harmonics <5% (full load) <5% (full load) <5% (full load) <5% (full load) <5% (full load) <5% (full load) <5% (full load) <5% (full load) <5% (full load)
  Rated power (VA/W) 1000/900 1000/900 2000/1800 2000/1800 3000/2700 3000/2700 6000/5400 6000/5400 10000/9000
  output power 24 factor 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting) 0.9 (can be set to 1.0 at 0~30°C, 1-3kVA needs software setting)
  Output voltage (Vac) 208/220/230/
240±1%
208/220/230/
240±1%
208/220/230/
240±1%
208/220/230/
240±1%
208/220/230/
240±1%
208/220/230/
240±1%
208/220/230/
240±1%
208/220/230/
240±1%
208/220/230/
240±1%
  Output frequency (Hz) Mains mode: synchronized with the grid; battery mode: 50/60±0.2% Mains mode: synchronized with the grid; battery mode: 50/60±0.2% Mains mode: synchronized with the grid; battery mode: 50/60±0.2% Mains mode: synchronized with the grid; battery mode: 50/60±0.2% Mains mode: synchronized with the grid; battery mode: 50/60±0.2% Mains mode: synchronized with the grid; battery mode: 50/60±0.2% Mains mode: synchronized with the grid; battery mode: 50/60±0.2% Mains mode: synchronized with the grid; battery mode: 50/60±0.2% Mains mode: synchronized with the grid; battery mode: 50/60±0.2%
  Waveform (THD) <2% (linear load), <3% (non-linear load) <2% (linear load), <3% (non-linear load) <2% (linear load), <3% (non-linear load) <2% (linear load), <3% (non-linear load) <2% (linear load), <3% (non-linear load) <2% (linear load), <3% (non-linear load) <1% (linear load), <3% (non-linear load) <1% (linear load), <3% (non-linear load) <1% (linear load), <3% (non-linear load)
  Switching time (ms) 0 0 0 0 0 0 0 0 0
  overload capacity 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms 100%-130% overload: maintain 1min; 131%-150%: overload maintain 1s; 150% or more: overload maintain 200ms Load<115%: long-term; 115%-130% overload: 10min; 131%-150% overload: 30s; over 150% overload: 0.5s Load<115%: long-term; 115%-130% overload: 10min; 131%-150% overload: 30s; over 150% overload: 0.5s Load<115%: long-term; 115%-130% overload: 10min; 131%-150% overload: 30s; over 150% overload: 0.5s
  output method output socket output socket output socket output socket Output socket + terminal block Output socket + terminal block Terminal block Terminal block Terminal block
  Overall efficiency Up to 95% Up to 95% Up to 95% Up to 95% Up to 95% Up to 95% Up to 95% Up to 95% Up to 95%
  DC start have have have have have have have have have
  communication function RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional) RS232, EPO (standard); USB, SNMP, dry contact, etc. (optional)
  panel display led led led led led led blue screen LCD blue screen LCD blue screen LCD
other features Audio noise (dB) <50 <50 <50 <50 <55 <55 <55 <55 <55
other features Alarm function Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit Battery low voltage, mains abnormality, UPS failure, output overload, output short circuit
other features Protective function Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection Battery undervoltage protection, overload protection, short circuit protection, over temperature protection, input overvoltage protection
other features Working temperature (ÿ) -5~40 -5~40 -5~40 -5~40 -5~40 -5~40 -5~40 -5~40 -5~40
other features environment humidity 0 ~ 95%, non-condensing 0 ~ 95%, non-condensing 0 ~ 95%, non-condensing 0 ~ 95%, non-condensing 0 ~ 95%, non-condensing 0 ~ 95%, non-condensing 0 ~ 95%, non-condensing 0 ~ 95%, non-condensing 0 ~ 95%, non-condensing
other features Dimensions (W×D×H) (mm) 45×360×225 45×360×225 90×400×330 90×400×330 90×400×330 90×400×330 230×502×553 190×422×337 190×422×337
other features Weight (kg) 9.2 4.5 17.7 8.5 22.9 9.2 54.5 11 12.5
 

Lihat detail lebih lanjut tentang Alliance Supplies Sdn Bhd
Alliance Supplies Sdn Bhd
Alliance Supplies Sdn Bhd Industrial Supplier Company in Malaysia, Melaka, Industrial Tools Supply Johor Bahru (JB), Selangor, Sarawak ~ Alliance Supplies Sdn Bhd