F701+ (Weighing Indicator)

F701+ (Weighing Indicator)

Category: Weighing Application Available
Purchasable on official site
For more information, visit our official website at imsmotion.com

Description

F701+

Functionally improved weighing indicator
 

Product outline

A weighing indicator F701 is functionally improved !!
Superb performance is achieved with consideration 
for convenience at the site

 

F701+ has outstanding abilities such as High-accuracy amplifier, high sampling rate & High-performance filter which is resistant to vibration.
Furthermore, various functions of Equivalent calibration, Sequential control, Set value restoration and Recovery from power failure are available.
F701+ is an ideal weighing indicator which considering performance and convenience.

 

 
 

High sampling rate & resolution

High-Speed A/D conversion and powerful digital processing capability of 500 times/sec.
High resolution of 1/10000 in all input range.
* It can be changed to 100times/sec.

F701+High sampling rate & resolution

Measurement can be performed quickly and precisely due to high speed A/D conversion.
 

Auto filter adjustment

Capable of adjusting filter automatically according to an operating condition. Helpful for setting at the test operation.

F701+Auto filter adjustment
 

Equivalent calibration

Equivalent calibration can be made easily by just inputting rated capacity and output of loadcell to F701+ with key button.

F701+Equivalent calibration
 

Recovery form temporary stop / power failure

Temporary measurement stop, and Operation restart mode are available. Measurement can be performed continuously from the middle .

F701+ Recovery form temporary stop / power failure
 

Set value restoration

Set value can be restored, in case set value is changed by mistake.

F701+Set value restoration
 

Various functions are available

Digital low pass filter
As it is resistant to vibration, measurement can be performed quickly and precisely.
*Conventional analog filter is also selectable

 

Sink type / source type are available
Type of I/O signal are selectable form Sink and Source.

 

Displaying accumulated value with one-touch
Accumulated value can be shown with one-touch

 

Connecting with printer by using RS-232C communication
Time data can be output for efficient data management.


Various optional interface
D/A converter, BCD output, RS-232C, RS485(Selectable from Modbus-RTU and UNI format), PROFIBUS-DP are available.
 

I/O board can be easily replaced on site
 

 

 

 

Specifications

Analog
Excitation voltage DC10V±5% Output current within 120mA 
Remote sense type Up to 4 350Ω load cells can be connected in parallel
Signal input range 0.53.0mV/V
Zero adjustment range Automatic adjustment by digital processing0.52.0mV/V
Gain adjustment range

Automatic adjustment by digital processing0.33.0mV/V

Min. input sensitivity 0.3μV/count
Accuracy
  • Non-linearity
  • within  0.01%/FS
  •  
  • Zero drift
  • within  0.2μV/ RTI
  •  
  • Gain drift
  • within  15ppm/
A/D converter Speed Selectable from 500 times/sec, 100 times/sec
Resolution 24bitbinary
Min. indicated resolution 1/10000
Secondary calibration Equivalent calibration
Min. indicated resolution during secondary calibration: 1/1000 (room temperature)
 
Filter
Analog Low-pass filterSelectable from 2, 4, 6, 8Hz 12dB/oct
Digital Low-pass filterSelectable from OFF, 1, 1.5, 2, 2.5, 3, 4, 5Hz
 
Display
Display unit Character height 18.5mmNumerical display (7 digits) by fluorescent display tube
Display value 5 digits, Sign; Minus sign displayed on most significant digit
Display frequency Selectable from 3, 6, 13, 25 times/sec
Capacity 5 digits
Min. scale division Can be set from 1 to 100
Over scale display LOAD A/D converter input over, LOAD A/D converter input minus over, 
OFL1 Net weight over, OFL2 Capacity +9 scale division, OFL3 Gross weight over
Center zero A true zero point or the center of each value is displayed.
Unit Selectable from kg/g/t/lb/N/None
Status display SP3/SP2/SP1/LOCK/ZT/ZALM/STAB/TARE/NET/GROSS/
HI LIM/HI/GO/LO/LO LIM/HOLD/NZ/CZ
 
Setting
Setting method Settings are made by operating the membrane keys.
Setting by RS-232C interface (option) and RS-485 interface (option) is also possible
Memory of set value Calibration value and a part of set value: NOV.RAM (nonvolatile RAM)
Other set values: F-RAM (nonvolatile RAM)
Protect of set value Protect can be set by Lock switch and Lock parameter.
Setting item

Upper limit, Lower limit, Near zero, Set point 1, Set point 2, Compensation, Over, Under, Final, Comparison inhibit time, Judging time, Complete output time, Compensation feeding time, Number of times for AZ, Number of times for judging, Auto free fall compensation regulation value, Tare setting, Weighing function 1, Weighing function 2, Weighing function 3, Sequence mode, Function key inhibited, Filter, Motion detect, Zero tracking, Setting value LOCK, Balance weight value, Capacity, Min. scale division, Net over, Gross over, DZ regulation value, Function selection, Compensation for gravitational acceleration, Zero calibration, Span calibration, Equivalent calibration, Input selection, Output selection, Moving average filter, Restart setting set point 1, Restart setting set point 2, Restart setting set point 3

 
External signal
You can specify whether PNP (Source) type or NPN (Sink) type when order the F701+.
Output signals
12 points
NZ, SP1, SP2, SP3, Under, Over, Lower limit, Upper limit, 
Stable, Output selection 1, Output selection 2, Output selection 3 
Output turns ON when transistor is ON.
* PNPsourcetype: External voltage must be prepared separately by customer.
Input signals
8 points
G/N, D/Z, One-touch tare subtraction, Input selection 1, 
Input selection 2, Input selection 3, Input selection 4, Input selection 5
Contact (relay, switch etc.) or non-contact (transistor, open collector etc.) can be connected.
* PNPsourcetype: External voltage must be prepared separately by customer.
 
Interface
2 optional interface can be added in addition the standard interface.
1(mark): only 1 option is available.
2(mark): only 1 option is available.
SIF 2-wire type serial interface
232 RS-232C communication interfaceOption1
485 RS-485 communication interfaceSelectable from Modbus-RTU, UNI formatOption1
BCO BCD parallel data output interface (Option)2
DAC D/A converter (Option)2
PRF PROFIBUS interface (Option) PROFIBUS-DPV0  2
 
General specification
Power supply voltage AC100240V1015free power source 50/60Hz
Inrush current 1.5A, 1ms AC100V average load condition cold start at room temperature
2.5A, 1ms AC200V average load condition cold start at room temperature
Power consumption 7W typ
Operating conditions Operation temperature1040桡Storage temperature2085桡
Humidity 85RH or lessnon-condensing
Dimensions 192W×96H×160DmmProjections excluded
Weight Approx. 1.5kg
 
Attachment
AC input cordNominal rating 125V2m 1
Load cell connector 1
Mini-screwdriver 1
57 series 24p connector for external input / output 1
Operation manual 1
BCD output connector ×1with BCD output option 1
D/A converter connector ×1with D/A converter option 1
 
 

Option

Model Interface
232 RS-232C communication interface
485 RS-485 communication interfaceSelectable from Modbus-RTU, UNI format
BCO BCD parallel data output interface
DAC D/A converter
PRF PROFIBUS interface PROFIBUS-DPV0
 
 

Optional accessories

Model Description
CAAC2P-P2 AC input cord 2m
CAAC3P-CEE7/7-P1.5 AC input cordVoltage resistance:250V1.5m
CA4131 6-wiredcable with JRC connector at one end 3m
CA4230 JRC-PRC 6-wiredconversion relay cable 0.3m
CA4311 JRC-PRC 6-wiredconversion relay cable 4-wired to 6-wired
for 520A use1m
CN3P-2P 3P-2P converter plug for AC input cord
CN10 Loadcell connectorJRC connector
CN21 57 series 36p connector for BCD output
CN23 57 series 24p connector for external input / output
CN34 D-Sub 9p connector for RS-232C
 