Description
40UV - Vertical
40UH - Horizontal
Airstream unit ventilators meet the strict indoor air quality requirements of schools, hospitals, and institutions. The 40UV units are compact, efficient, and easy to install and maintain. Units are designed to provide economic, dependable long-term performance.
Performance Features
-
Ventilation rate is certified per AHRI Standard 840
-
Insulated outdoor air damper provides control of ventilation air and can fully open to provide free cooling
-
Cooling coil has a full-depth design to prevent the build-up of humidity in the room
-
Double sloped condensate drain pan prevents standing water
-
One-piece filter cleans the air before it is introduced into the room
-
Draw-thru blower arrangement distributes air across the entire coil face for uniform discharge temperatures
-
Sound levels are rated in accordance with ARI standard 350
Reliability Features
-
Die-formed, heavy-gage steel cabinet provides secure, dent-resistant protection for internal components
-
Cabinet exterior has a baked-on polyurethane-coated finish for corrosion resistance
-
Rotating components are isolated from the rest of the unit for vibration-free operation
-
Safety cutouts and interlock switches ensure safe performance
-
Cartridge fuses provide motor and control protection
-
Efficient direct drive helps to maintain low operating costs and also reduces maintenance requirements
-
Unit listed with ETL and ETL, Canada in accordance with UL 1995 standards
Maintenance Features
-
Tamper resistant hex head panel fasteners panels and doors offer easy service access without special tools
-
Large compartments for wiring and piping simplify maintenance procedures
-
Modular design provides enhanced structural rigidity for trouble free operation and simplified maintenance
-
The blower, coil, and damper modules, can be removed without disassembling the unit
-
Label information adhered to each unit includes model, size, coil information, electrical information and tagging date
Installation Features
-
Coil hand connections are reversible without unit modification
-
Drain pans can be configured for right or left hand connection in the field
-
Piping, drain and wiring diagrams are readily accessible
-
Built-in leveling legs
-
Factory-installed control packages
-
Factory-wired and assembled valve packages
-
Single point electrical connection
Factory-Installed Options
-
ECM motors
-
Carrier UV Open BACnet controller
-
DDC ready controls package for ease of field installing a controller
-
Factory mounting of field-supplied third party DDC controls
-
Chilled water cooling coil
-
Hot water heating coil
-
Steam heating coil
-
DX cooling coil
-
Electric resistance heating coil
-
Stainless steel drain pan
-
Outdoor air/return air damper
-
Face and bypass damper
-
Decorative colors
-
Permanent or throwaway filters
-
Double deflection discharge grille
-
Bar stock discharge grille with screen
-
Discharge duct color
-
Draft elimination return
-
Adapter back
-
Pipe tunnel
-
Heavy gauge exterior panel
Field-Installed Accessories
-
Wall-mounted temperature and IAQ sensors
-
Valve packages
-
Permanent or throwaway filters
-
End panels
-
Barometric relief damper
-
Outside air louver
-
Barometric relief damper louver
-
Unit sub-base
-
Unit utility compartment
-
Cabinet filler sections
-
Draft stop enclosure
-
Filler sections
-
Pipe enclosures
-
Sink and bubbler units
-
Storage cabinet
Unit 40UV, UH |
050* |
075 |
100 |
125 |
150 |
200† |
Nominal Airflow (Cfm) |
500 |
750 |
1000 |
1250 |
1500 |
2000 |
Fans |
Quantity |
1 |
2 |
3 |
4 |
5 |
5 |
Diameter (in) |
8.32 |
8.32 |
8.32 |
8.32 |
8.32 |
9.5 |
Width (in) |
8 |
8 |
8 |
8 |
8 |
6 |
40UV Filters |
Nominal Size (in) (1 in. thick) |
9-1/4 x 24-1/4 |
9-1/4 x 36-1/4 |
9-1/4 x 48-1/4 |
9-1/4 x 60-1/4 |
9-1/4 x 72-1/4 |
-- |
Nominal Size (in) (2 in. thick) |
9-1/4 x 24-1/4 |
9-1/4 x 36-1/4 |
9-1/4 x 48-1/4 |
9-1/4 x 60-1/4 |
9-1/4 x 72-1/4 |
-- |
Quantity |
1 |
1 |
1 |
1 |
1 |
-- |
40UH Filters |
Nominal Size (in) (1 in. thick) |
-- |
9-1/4 x 36-1/4 |
9-1/4 x 48-1/4 |
9-1/4 x 60-1/4 |
9-1/4 x 72-1/4 |
9-1/4 x 72-1/4 |
Nominal Size (in) (2 in. thick) |
-- |
9-1/4 x 36-1/4 |
9-1/4 x 48-1/4 |
9-1/4 x 60-1/4 |
9-1/4 x 72-1/4 |
9-1/4 x 72-1/4 |
Quantity |
-- |
1 |
1 |
1 |
1 |
1 |
40UV Shipping Weight** (Approx lb) |
16-5/8 in Deep Unit |
330 |
400 |
480 |
590 |
660 |
-- |
21-7/8 in Deep Unit |
340 |
410 |
490 |
605 |
675 |
-- |
40UH Shipping Weight** (Approx lb) |
34 in Deep Unit |
-- |
420 |
500 |
620 |
690 |
-- |
39-1/2 in Deep Unit |
-- |
500 |
600 |
740 |
830 |
-- |
43-1/2 in Deep Unit |
-- |
530 |
640 |
790 |
880 |
1020 |
47-1/2 in Deep Unit |
-- |
-- |
-- |
-- |
-- |
1050 |
40UV Installed Weight** (Approx lb) |
16-5/8 in Deep Unit |
315 |
380 |
460 |
570 |
640 |
-- |
21-7/8 in Deep Unit |
325 |
390 |
470 |
595 |
655 |
-- |
40UH Installed Weight ** (Approx lb) |
34 in Deep Unit |
-- |
405 |
580 |
600 |
670 |
-- |
39-1/2 in Deep Unit |
-- |
485 |
580 |
720 |
810 |
-- |
43-1/2 in Deep Unit |
-- |
515 |
620 |
770 |
860 |
1000 |
47-1/2 in Deep Unit |
-- |
-- |
-- |
-- |
-- |
1030 |
Coil Water Weight (Approx lb per row of coil) |
1.0 |
1.5 |
2.0 |
2.4 |
2.7 |
2.7 |
Coil Connections (in OD) |
Return |
Supply |
Water Coils with 1-5 Rows |
7/8 |
7/8 |
Steam Coils (All Units) |
7/8 |
1-1/8 |
|
Suction |
Liquid |
DX Coils |
7/8 |
3/8 |
Condensate Drain |
7/8 |
DX = Direct Expansion
*40UV only.
†40UH 43-1/2 and 47-1/2 in. deep units only.
**Weight based on damper-controlled unit with 5-row coil and factory-installed controls.