| Item | Data | ||
| APPROVAL | |||
| Test standard | UL1059 | ||
| Pitch [mm] | 8.8 | ||
| Poles | 02-24P | ||
| UL1059Test data | UL File Number E228872 | ||
| Use group | B | C | D |
| Rated voltage [V] | 600 | 600 | 600 |
| Rated current [A] | 20 | 20 | 5 |
| Rated connection capacity (solid/stranded) [AWG] | 24-Dec | ||
| Rated torque [Lb. in] | 8.78 | ||
| General data | / | ||
| Screw | M3.5 | ||
| Inflammability class UL94 | V-0 | ||
| Ambient temperature [℃] | -40~+105 | ||
| Relative humidity | 5%-95% | ||
| Inspection standard | MIL-STD-105E II | ||
| AQL | 0.65 | ||
| Warranty | 12 months | ||
| Material and plating | / | ||
| Housing | PA66 | ||
| Screw | Steel,Ni plated | ||
| Contact | Copper,Sn plated | ||
| Fastener | Steel,Ni plated | ||
| Recommended stripping length 7-8mm; | |||
| 1.)For solid wire, stripping wire to the appointed length, then tightening with rated torque. | |||
| 2.)For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque. | |||
| Tightening process should be steady, can’t use explosive force. | |||