Model No. |
AP-AB1208 |
Input Voltage |
DC 24V |
Input current |
<600mA |
Power |
10W |
Working Voltage |
±5000V |
Working method |
Pulse AC |
Emitter electrode |
SUS |
Discharge structure |
Resistance coupling |
Output frequency |
1,3,5,10,20,30,50Hz;(Factory setting:30Hz) |
Duty Ratio |
10%—90% |
Working range |
L*W*H:{385-410(Probe distance 25mm);460-2960(Probe distance 50mm)}*300*1000mm |
Working distance |
100→1000mm |
Ion balance |
≤|±30V|(AVE) |
Discharge speed |
≤2S |
Warning indicate |
Power input indicator,High Voltage indicator(Green is normal,Red is abnormal) |
Status monitoring |
Series network monitoring / wireless monitoring |
Airflow pressure |
≤0.6MPa |
air source connector With throttle valve |
Φ8-G1/8 Black |
Working temperature |
0℃-50℃ |
Working humidity |
<70% |
Dimension |
L*W*H:{385-410(Probe distance50mm);460-2960(Probe distance50mm)}*35*78.4mm |
Bar body material |
Flame retardant PVC、ABS、AL、SUS |
Accessories |
Flexible 180° install bracket |
Power adapter |
GRT-240200: DC24V 2A,Dual network port output,123*61*40.5mm(L*W*H) |
Power adapter cable length |
2.5m |
Warranty |
1 Year |
Certificate |
CE |