TM-1012 AC Clamp Phase
Application
It can be used for CURRENT, VOLTAGE and FREQUENCY measurements on installations of surge voltage category III up to 600 V, voltage between Phase and Earth (fixed installations) and for current measures up to 400A.Specifications
ACA (Auto/Manual) | |||
Range | Resolution | Accuracy 50Hz~60Hz |
Overload protection |
200A | 0.1A | ±(1.5%+10) | 600A RMS (60 seconds) |
400A | 1A |
DCV (Auto/Manual) | ||||
Range | Resolution | Accuracy | Input impedance | Overload Protection |
2V | 1mV | ±(0.8%+2) | 11M!& | DC/AC 660V rms |
20V | 10mV | 10M!& | ||
200V | 100mV | |||
600V | 1V | ±(1.0%+2) |
ACV (Auto/Manual) | ||||
Range | Resolution | Accuracy 50Hz~500Hz |
Input impedance | Overload Protection |
2V | 1mV | ±(1.0%+3) | 11M!& | DC/AC 660V rms |
20V | 10mV | 10M!& | ||
200V | 100mV | |||
600V | 1V | ±(1.2%+3) |
Resistance (Auto/Manual) | ||||
Range | Resolution | Accuracy | Max. Open Loop voltage |
Overload protection |
200Ω | 0.1Ω | ±(1.0%+5) | About-1.5VDC | DC/AC 600V rms (60 Second) |
2kΩ | 1Ω | ±(1.0%+3) | About-0.45 VDC | |
20kΩ | 10Ω | |||
200kΩ | 100Ω | |||
2MΩ | 1kΩ | |||
20MΩ | 10kΩ | ±(3.0%+3) |
Continuity test | |||
Range | Buzzer | Max. Open Loop voltage |
Overload protection |
Below 25Ω | About-1.5 VDC | 600A rms |