Autonics Multi-Functional Digital Indicators KN-2201W-Peak

Autonics Multi-Functional Digital Indicators KN-2201W-Peak

Category: Controller Available
For more information, visit our official website at ims.com.my

Description

Autonics Multi-Functional Digital Indicators KN-2201W-Peak ( With Peak Mode Holding Function)

 
Main features
 
• High accuracy with 16bit ADC (±0.2% F.S.)
• Max. display range: 19999 to 19999
• Multi-input
: Thermometer 12 types, RTD 5 types, analog (mV, V, mA) 6 types
• Auto display color change function (for error or alarm)
• Various output options : 4EA or 2EA alarm output, 4-20 mA transmission output (isolated), RS485 communication output
※ Full output option model is available.
(alarm output 4EA + RS485 communication output + transmission output)
• Various functions
: High/Low peak monitoring, sensor break alarm output (burn-out), input correction, digital input (DI), user input range, display scale, transmission output scale, etc.
• Built-in power supply for sensor (24 VDC)
 
Specification Table 

Series KN-2000W
Power supply AC voltage 100-240 VAC 50 to 60 Hz
DC voltage 24 VDC
Allowable voltage range 90 to 110% of rated voltage
Power consumption AC voltage Max. 8 VA
DC voltage Max. 3 W
Display method 4 1/2 digit: 7 Segment LED Display (selectable red, green, yellow), character size : W10 mm x H17 mm
Input type RTD JPt100Ω, DPt100Ω, DPt50Ω, Cu50Ω, Cu100Ω (5 types)
Thermocouple K, J, E, T, R, B, S, N, C (W5), L, U, PLII (12 types)
Analog • Voltage : ±1.0000 V, ±50.00 mV, ±200.0 mV, -1.000 V~10.000 V (4 types) 
• Current : 4.00~20.00 mA, 0.00-20.00 mA (2 types)
Digital input • Contact input : Max. 2 kΩ in ON,Max. 90 kΩ in OFF 
• Non-contact input: Residual voltage max. 1.0 V in ON, Leakage current max. 0.03 mA in OFF 
• Outflow current: Approx. 0.2 mA
Sub output Alarm output 2-point: Relay contact capacity 250 VAC 3 A 1c, 4-point: Relay contact capacity 250 VAC 1 A 1a
Transmission output ISOLATED DC 4-20 mA (PV transmission) load resistance max. 600Ω 
(accuracy: ±0.2%F.S., resolution: 8000)
Communication output RS485 (Modbus RTU)
Display accuracy ±0.2% F.S. ±1digit (25±5℃) 
±0.3% F.S. ±1digit (-10 to 20℃, 30 to 50℃) 
In case of thermocouple and below -100℃ input, [ ±0.4% F.S. ]±1digit 
※TC-T, TC-U is min. ±2.0℃
Setting method Set by front keys, or RS485 communication
Alarm output hysteresis Set ON/OFF interval (1 to 999 digit)
Sampling cycle Analog input: 100 ms, Temperature sensor input: 250 ms
Dielectric voltage 200 0VAC 50/60 Hz for 1 min. (between input terminal and power terminal)
Vibration 0.75 mm amplitude at frequency of 5 to 55 Hz (for 1 min.) in each of X, Y, Z directions for 2 hours
Relay life cycle 2-point Mechanical: Min. 10,000,000, Electrical: Min. 100,000 (250 VAC 3 A resistance load)
4-point Mechanical: Min. 20,000,000, Electrical: Min. 500,000 (250 VAC 1 A resistance load)
Insulation resistance Min. 100 MΩ (at 500VDC megger)
Noise resistance Square shaped noise by noise simulator (pulse width 1 ㎲) ±2 kV
Memory retention Approx. 10 years (non-volatile semiconductor memory type)
Environ- ment Ambient temperature -10 to 50℃, storage: - 20 to 60℃
Ambient humidity 35 to 85%RH, storage: 35 to 85%RH
Approval CE
Unit weight Approx. 200 g





Caution For Your Safety
 
• For connecting the power, use a crimp terminal(M3.5, min. 7.2 mm).
• The connection of this unit should be separated from the power line and high voltage line in order to prevent inductive noise.
• Install a power switch or a circuit breaker to supply or cut off the power.
• Switch or circuit breaker should be installed nearby users for convenient control.
• Do not use this unit near the high frequency instruments (high frequency welding machine & sewing machine, large capacity SCR controller).
• When supplying input, if HHHH or LLLL is displayed, measured input may have problem. Turn off the power and check the line.
• Installation environment.
① It shall be used indoor.
② Pollution Degree 2
③ Altitude max. 2,000 m
④ Installation category Ⅱ
• It may cause malfunction if above instructions are not followed


iMS Motion Solution (Johor) Sdn Bhd (Company Registration 1098771-W)
 
No.7, Jalan Sasa 4,Taman Gaya, 81800 Ulu Tiram, Johor Bahru, Johor. Malaysia.
TEL:+607-8635240 FAX: +607-8637240
MOBILE: +6019-6774477
EMAIL: [email protected]WhatsApp  | www.ims.com.my
HOTLINE : 1700-818-330
whatsapp us now !

Brand Name
MEISTER | GGM | Sanyo Denki | ElectroCraft | EDrive | SHIHLIN ELECTRIC | AUTONICS | UI Robot | Mitsubishi CNC | PANASONICApex Dynamics | NISSEI GTR | UNIPULSE | CREVIS
 
MOTION DEVICES SPECIALIST | SYSTEM and CONTROL INTEGRATION |
| Induction Motor | Speed Control Motor | Reversible Motor |Brake Motor |BLDC Motor |DC Motor |Planetary Gear Motor | Servo Motor | Stepping Motor | Linear Actuator Motor | Lead Screw Motor|Close Loop Stepping Motor | Customization Motors | Right Angle Gear Head | Precision Gear Reducer |PLC | Motion Controller |HMI /Touch Screen| Inverter |CNC Controller |Multi Axis Robots |IPC | SCADA |Monitoring Software | Embeded PC | Remote IO |TPC | Motion Card | Loadcell |PPC |
 
Return / Refund Policy : 
All goods sold are not returnable & we accept goods ex-change with equal or lower value of good purchased. If the ex-change items are higher than purchased items, buyer shall top up the differential cost. All payment made are not refundable, please confirm the purchase items code & cost with our sales representative before place orders.
 
Shipping and Fulfillment :
Thank you for your purchase. Once we have confirmed your payment, we will prepare and ship out your order out within 24-48 hours.( For ex-stock items only, Indent items subject to delivery stated in quotation & conversation in emails). Once your order has been shipped out, you will receive an email notification with the tracking number and tracking details inside.
 
Private Policy
General Statement of Principles 
As described in detail below, any information we gather at this web site is strictly for our use and is not shared with any other entity, public or private, for any reason - period. We will not sell or give away any lists or other data that we may retain and we do not purchase such information from other sources.
Statistical Data 
Our servers (as most) track IP addresses and referring pages to help with site maintenance and improvements. This data is viewed only as anonymous statistics to show the busiest times of the day or week, pages with errors and how effective our advertising has been. This information is not used for any other purpose.
Personal Information Collected - Order Forms
With the exception of credit card info, we store the information from your order form to allow us to track consulting issues or refer to a previous order to help provide some customer service. You may elect to have your information completely removed from this system by e-mailing us at [email protected] with your request. We do not store any type of sales information.
Information Correction or Removal 
If you wish to correct, update or remove any information about you that may be in our records, please send us e-mail at [email protected] with the details of your request. If you wish to contact us further, please find complete contact information on our contact page.
Cookies
Cookies are files with small amount of data, which may include an anonymous unique identifier. Cookies are sent to your browser from a web site and stored on your computer's hard drive. We use 'cookies' to store your cart contents for you. You can instruct your browser to refuse all cookies or to indicate when a cookie is being sent. However, if you do not accept cookies, you may not be able to use the checkout section of our site.
 
Changes To This Privacy Policy
This Privacy Policy is effective as of 1st Jan 2019 and will remain in effect except with respect to any changes in its provisions in the future, which will be in effect immediately after being posted on this page.

More detail about IMS Mechatronics Sdn Bhd
IMS Mechatronics Sdn Bhd
IMS Mechatronics Sdn Bhd Motion Solutions Johor, Control Components Supplier Malaysia, Motion Devices Johor Bahru (JB) ~ IMS Mechatronics Sdn Bhd
Contact Us flagMalaysia