Applications |
Evaluation unit |
Compatible sensor types |
Two-hand controls Type III C, in accordance with EN 574 |
Safety integrity level |
SIL3 (IEC 61508)
SILCL3 (EN 62061) |
Category |
Category 4 (EN ISO 13849) |
Performance level |
PL e (EN ISO 13849) |
Reset |
Automatic |
Discrepancy monitoring |
✔ |
Cross circuit detection and sequence monitoring |
✔ |
External device monitoring (EDM) |
Integrated |
Number of enable current contacts |
2 |
Number of application diagnostic outputs |
1 |