BL983329-1 TDS Mini Controller (0 to 999 ppm)

BL983329-1 TDS Mini Controller (0 to 999 ppm)

分类: Mini Controllers 当前有货 (数量:1)
可在官方网站购买
RM 1111.00 欲了解更多详情,请游览我们的官方网站 hannamalaysia.com

详情

The BL983329 is a compact, panel mounted, process controller for measuring total dissolved solids (TDS) in a process stream that is within the 0 to 999 ppm (mg/L) range. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve.

*The BL983329 uses a 0.5 conversion factor in which 100 μS/cm = 50 ppm.

Multicolor LED Indicator

LED changes color based on status.

Fire Retardant Casing

For additional safety the controllers outer case is made of fire resistant plastic.

Splash Resistant Cover

A clear plastic cover protects the face panel from dirt and liquids.
 

BL983329

Adjustable Dry Contact Dosing Relay

The BL983329 features a dosing relay that is activated when the reading is above a user programmable set point.

Programmable Overdose Protection

For enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.

Relay Control Override

With the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.

Multicolor LED Indicator

Multicolor LED indicator allows an operator to quickly check the status of the controller.

  • Green = Meter in measurement mode and reading is below the set point.
  • Orange/Yellow = Reading is above the set point and the relay is activated.
  • Blinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.
BL983329

Fuse Protected Dosing Contacts

The relay dosing contact is rated for up to a 2A load and is fuse protected.

Labeled Termination Connections

Quick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.

HI7634

1/2'' NPT Male Threaded Amperometric Probe for Mounting In-line*

The BL983329 mini controller uses the HI7634 conductivity probe that is available with different cable lengths.

*HI7634 is not included and must be ordered separately



 
SKU BL983329-web
Product Name TDS Mini Controller (0 to 999 ppm) - BL983329
Quote Required Yes
TDS Range 0 to 999 ppm (mg/L)
TDS Resolution 1 mg/L ppm (mg/L)
TDS Accuracy ±2% f.s.
TDS Calibration manual, with CAL trimmer
EC/TDS Temperature Compensation automatic from 5 to 50°C (41 to 122°F) with β =2%/oC
EC to TDS Conversion Factor 0.5
EC/TDS Dosing Relay maximum 2A (fuse protected), 250 Vac, 30 VDC
EC/TDS Dosing Set Point adjustable from 0 to 999 mg/L (ppm)
Dosing Control contact closed when measure > setpoint
Over Dosing Control adjustable, typically from 5 to approximately 30 minutes
Power Supply models “-0”
Dimensions 83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)
Weight models “-0”
Ordering Information BL983329-1 (115/230 VAC) and BL983329-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.

更多 Hanna Instruments (M) Sdn Bhd 相关资料
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd Measuring Instruments Selangor, Photometers Supply Penang, Sabah, Test Equipments Supplier Malaysia ~ Hanna Instruments (M) Sdn Bhd