Level measurement and point level detection in the anhydrous ammonia storage tank

Level measurement and point level detection in the anhydrous ammonia storage tank

分类: Refining and petrochemical 当前有货
欲了解更多详情,请游览我们的官方网站 vginstruments.com.my

详情

Anhydrous ammonia storage tank

Level measurement and point level detection in the anhydrous ammonia storage tank

Level measurement and point level detection in the anhydrous ammonia storage tank
 

Process data

Measuring task
Level measurement and point level detection
Measuring point
Bullet
Measuring range up to
3 m
Medium
Anhydrous ammonia
Process temperature
-30 … +15 °C
Process pressure
+3 … +10 bar
Special challenges
Vapour permeation

Application

During the sulfur removal process, nitrogen is converted into ammonia through a water wash process to be sold for fertilizer production. Stringent environmental restrictions and the high hazard potential make secure control of the levels in ammonia handling processes absolutely necessary.