Product Details:
Power consumption | 230/ 240 V ac (24V DC backup) |
24V DC requirement | 19A |
Pwr consumption (load) ac | 3A |
Pwr consumption (s/by) | 0.4V |
Input sensitivity | 1V / 10 K Ohm |
Input gain control | -15 dB ~ 0 dB |
Input connection | XLR balanced line input |
Rated output (rms) | 240W |
Output voltage (4 Ohm) | 31 V rms |
Output imp ( 70 V line) (100 V line) |
21 V rms 42 |
Frequency response | 180 ~ 17 KHz (+/- 3dB at 1 KHz with low cut |
S/N ratio | >60 dB (@ 1 KHz) |
THD + N | <0.18% |
Protections | Thermal, momentary output short circuit, AC and DC circuit breaker, Input signal clip |
Indicators | AC mains, Clip, Protect, Input level |
Cooling system | Dual speed fan with heat sensing |
Dimension (W x H x D) | 133 x 482 x 300 mm |
Net Weight | 20.5 kg |