ZS Outdoor Air Sensors ZS-OA

ZS Outdoor Air Sensors ZS-OA

分类: Carrier 当前有货
欲了解更多详情,请游览我们的官方网站 unitedfaith.com.my

详情

Temperature Only, Temperature Plus Humidity

The Carrier ZS line of communicating outdoor air sensors are designed to measure the air temperature and/or humidity outdoors. Designed for outdoor mounting, the UV-resistant plastic shield keeps the sensor out of the sunlight and allows for excellent air circulation. These outdoor sensors have etched Teflon® lead wires and can withstand high humidity and condensation environments. They are made to perform in a wide range of temperature and moisture conditions.

The ZS outdoor air sensors connect directly to the dedicated sensor network (Rnet) of a Carrier i-Vu controller. This communicating sensor network supports up to 15 ZS sensors through a single port, eliminating the need to consume multiple inputs on the controller.
 

Averaging temperature sensor probe: Bendable aluminum / 3/16 in. diameter / Length of 8, 12, or 24 ft. specified at time of order

Sensing Element
Temperature Range: 20° to 120°F (-5° to 50°C)
Accuracy: ±0.36°F (0.2°C)
Humidity Range: 10% to 90%
Accuracy: Humidity is calibrated at 73°F (23°C) ±2.0% typical. Less than 0.5% drift per year.
Sensor
Temperature Range: 20° to 120°F (-5° to 50°C)
Accuracy: ±0.9°F (0.5°C)
Humidity Range: 10% to 90%
Accuracy: Humidity is calibrated at 73°F (23°C). ±2.0% typical. Less than 0.5% drift per year.
Enclosure Material Polycarbonate, UL94V-0
Enclosure Rating NEMA 4, IP66, UV rated
Enclosure Dimensions Width: 5 in. (12.7 cm)
Height: 4.15 in. (10.54 cm)
Depth: 2.5 in. (6.35 cm)
Probe Temperature sensor probe: Vented polycarbonate shield, .5 in. (1.27 cm) OD 1.2 in. (3.05 cm)
Temperature/humidity sensor probe:ABS with SS filter 1.0 in. (2.5 cm) diameter 2.4 in.
Sensing element shield Vented polycarbonate shield
0.5 in. (1.27 cm) outside diameter
1.2 in. (3.05 cm) long with 1/2 in. NPT threads
Power Requirements 12 Vdc @ 6 mA
Power Supply The 4-conductor Rnet cable from a controller supplies +12 Vdc @ 210 mA. For additional power, use an external power supply. Use the above power requirements to calculate the size of the external power supply. The controller and the external power supply must share a common ground.
Communication 115 kbps
Environmental operating range -40 to 158°F (-40 to 70°C)
Mounting 3/16 in. holes
Listed by FCC Part 15-Subpart B-Class B, CE

更多 United Faith Sdn Bhd 相关资料
United Faith Sdn Bhd
United Faith Sdn Bhd Air Conditioner Parts Supplier Selangor, Air Cond Services Kuala Lumpur (KL), Refrigeration Tools Malaysia, Singapore ~ United Faith Sdn Bhd