48KC WeatherMaker® rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, “no-strip screw” collars, and handled access panels, we’ve made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with Puron® (R-410A) refrigerant at the factory. The units are factory tested in both heating and cooling modes.
Gas Heating/Electric Cooling Units
3 to 5 Nominal Tons
Factory-Installed | Field-Installed | |
Cabinet | ||
Thru the base electrical or gas line connections | X | X |
Hinged access panels | X | |
Coil Options | ||
Cu/Cu indoor and/or outdoor coils |
X | |
Pre-coated outdoor coils | X | |
Premium, e-coated outdoor coils | X | |
Humidity Control | ||
Humidi-MiZer adaptive dehumidification system (3-phase models only) | X | |
Condenser Protection | ||
Condenser coil hail guard (louvered design) | X | X |
Controls | ||
Thermostats, temperature sensors and subbases | X | |
PremierLink DDC communicating controller | X | X |
RTU Open multi-protocol controller | X | X |
Smoke detector (supply and/or return air) | X | |
Time Guard II compressor delay control circuit | X | |
Filter status switch | X | |
Fan status switch | X | |
Economizers & Outdoor Air Dampers | ||
EconoMi$er IV (for electro-mechanical controlled RTUs) |
X | X |
EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD) |
X | X |
EconoMi$er 2 (for DDC controlled RTUs) | X | X |
Ultra-low leak economizer dampers | X | X |
Motorized 2-position outdoor air damper | X | X |
Manual outdoor dir damper | X | |
Barometric relief | X | X |
Power exhaust | X | |
Economizer Sensors & IAQ Devices | ||
Single dry bulb temperature sensors | X | X |
Differential dry bulb temperature sensors | X | |
Single enthalpy sensors | X | X |
Differential enthalpy sensors | X | |
CO2 sensor (wall, duct, or unit mounted) | X | X |
Gas Heat | ||
Liquid propane (LP) conversion kit | X | |
High altitude conversion kit | X | |
Indoor Motor & Drive | ||
Multiple motor and drive packages | X | |
Low Ambient Control | ||
Winter start kit | X | |
Motormaster head pressure controller | X | |
Power Options | ||
Convenience outlet (powered) | X | |
Convenience outlet (unpowered) | X | |
Non-fused disconnect | X | |
Roof Curbs | ||
Roof curb 14'' (356mm) | X | |
Roof curb 24'' (610mm) | X |
Nominal Cooling Ton Size | Cooling Stages | AHRI Efficiency (SEER) EER | Dimensions (in) LxWxH | Low Gas Heating Input (MBtuh) | Medium Gas Heating Input (MBtuh) | High Gas Heating Input (MBtuh) | Approx. Unit Weight (lbs) |
---|---|---|---|---|---|---|---|
3 | 1 | (14.0) | 74x47x33 | 72 | 115 | - | 490 |
4 | 1 | (14.0) | 74x47x33 | 72 | 115 | 150 | 544 |
5 | 1 | (14.1) | 74x47x41 | 72 | 115 | 150 | 597 |