WeatherMaster® High-Efficiency Single-Packaged Rooftop Units 48HC Gas Heating : Electric Cooling with Puron® (R-410A) Refrigerant 3 to 25 Nominal Tons

WeatherMaster® High-Efficiency Single-Packaged Rooftop Units 48HC Gas Heating : Electric Cooling with Puron® (R-410A) Refrigerant 3 to 25 Nominal Tons

分类: Carrier 当前有货
欲了解更多详情,请游览我们的官方网站 unitedfaith.com.my

详情

Gas Heating / Electric Cooling with Puron® (R-410A) Refrigerant

3 to 25 Nominal Tons

48HC WeatherMaster® rooftop units were designed by customers for customers. With a gauge plug, centralized control center, plug & play accessory board, ''no-strip screw'' collars, and handled access panels, we’ve made the unit easy to install, easy to maintain, and easy to use. Units are pre-wired and pre-charged with environmentally sound Puron® (R-410A) refrigerant at the factory. The units are factory tested in both heating and cooling modes.


carrier-AHRI-210-240-Unitary-Small-AC
carrier-intertek-ETL-listed-C-US
carrier-c-ul-us
carrier-AHRI-340-360-Unitary-Large-AC

 

Performance Features

Maintenance Features

Installation Features

Reliability Features

Factory-Installed Options

  • Cabinet
    • Thru-the-base electrical or gas-line connections
    • Hinged access panels
    • Foil-faced insulation
  • Coil Options
    • Cu/Cu indoor and/or outdoor coils
    • Pre-coated outdoor coils
    • Premium, E-coated outdoor coils
  • Humidity Control
    • Humidi-MiZer Adaptive dehumidification system
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • ComfortLink™ DDC communicating controller
    • PremierLink™ DDC communicating controller
    • RTU OPEN™ open-protocol controller
    • Smoke detector (supply and/or return air)
  • Energy Recovery
    • EnergyX® Factory Integrated Energy Recovery
  • Economizers & Outdoor
    • Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper (sizes 17-28)
    • Barometric relief
    • Power exhaust (sizes 17-28)
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Single enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Gas Heat
    • Stainless steel heat exchanger
    • Flue discharge deflector
  • Indoor Motor & Drive
    • Multiple motor and drive packages
    • Staged Air Volume (SAV) Indoor Fan Speed System (sizes 08-28)
  • Low Ambient Control
    • Motormaster® head pressure controller
  • Power Options
    • Convenience outlet (powered)
    • Convenience outlet (unpowered)
    • Non-fused disconnect
    • HACR Circuit Breaker

Field-Installed Accessories

  • Cabinet
    • Thru-the-base electrical or gas-line connections
  • Condenser Protection
    • Condenser coil hail guard (louvered design)
  • Controls
    • Thermostats, temperature sensors, and subbases
    • PremierLink™ DDC communicating controller
    • RTU OPEN™ open-protocol controller
    • Smoke detector (supply and/or return air)
    • Time Guard II compressor delay control circuit
  • Energy Recovery
    • EnergyX® Factory Integrated Energy Recovery
  • Economizers & Outdoor
    • Air Dampers
    • EconoMi$er IV (for electro-mechanical controlled RTUs)
    • EconoMi$er X (for electro-mechanical controlled RTUs with CA Title 24 FDD)
    • EconoMi$er2 (for DDC controlled RTUs)
    • Ultra-low leak economizer dampers
    • Motorized 2 position outdoor-air damper
    • Manual outdoor-air damper
    • Barometric relief
    • Power exhaust
  • Economizer Sensors & IAQ Devices
    • Single dry bulb temperature sensors
    • Differential dry bulb temperature sensors
    • Single enthalpy sensors
    • Differential enthalpy sensors
    • CO2 sensor (wall, duct, or unit mounted)
  • Gas Heat
    • Liquid propane (LP) conversion kit
    • High altitude conversion kit
  • Low Ambient Control
    • Winter start kit
    • Motormaster® head pressure controller
  • Roof Curbs
    • Roof curb 14” (356mm)
    • Roof curb 24” (610mm)
Nominal Cooling Ton Size Cooling Stages AHRI Efficiency (SEER) EER Dimensions (in) LxWxH Low Gas Heating Input (MBtuh) Medium Gas Heating Input (MBtuh) High Gas Heating Input (MBtuh) Approx. Unit Weight (lbs)
3 1 (15.0) 74 x 47 x 33 72 115 -- 505
4 1 (15.6) 74 x 47 x 41 72 115 150 590
5 1 (15.2) 74 x 47 x 41 72 115 150 600
6 1 12.0 88 x 59 x 41 72 125 150 765
7.5 2 12.0 88 x 59 x 49 125 180 224 925
8.5 2 12.0 88 x 59 x 49 125 180 224 925
10 2 12.0 88 x 59 x 49 180 224 250 1099
10 2 11.5 88 x 59 x 49 180 224 250 1099
12.5 2 12.2 116 x 63 x 57 150 180 240 1430
15 2 12.0 128 x 87 x 49 220 310 400 1892
17.5 2 12.0 141 x 87 x 49 220 310 400 2102
20 2 12.0 141 x 87 x 57 220 310 400 2247
25 2 11.2 58 x 87 x 57 220 310 400 2292

更多 United Faith Sdn Bhd 相关资料
United Faith Sdn Bhd
United Faith Sdn Bhd Air Conditioner Parts Supplier Selangor, Air Cond Services Kuala Lumpur (KL), Refrigeration Tools Malaysia, Singapore ~ United Faith Sdn Bhd