详情
Gas Heating / Electric Cooling Units with Puron® (R-410A) Refrigerant
30 to 100 Nominal Tons
48P2 – Vertical CV/SAV
48P3 – Vertical VAV
48P4 – Horizontal CV/SAV
48P5 – Horizontal VAV
Carrier P Series rooftop units are pre-wired and factory-tested in both cooling and heating modes. All models feature an industrial grade cabinet with fully hinged access panels. Forward-curved supply fans provide performance of up to 4 in. external static pressure (ESP) and 6 in. ESP with optional airfoil supply fans.
Units are available in constant volume (CV), staged air volume (SAV), or variable air volume (VAV) applications, with a wide variety of gas heating options. Units come with the ComfortLink™ DDC (direct digital control) control system, scroll compressors on independent thermostatic expansion valve (TXV) controlled refrigeration circuits.
Performance Features
-
Multiple high-efficiency scroll compressors include a crankcase heater and vibration isolation
-
Up to 8 steps of cooling capacity control with intertwined evaporator coils for full-face active operation at part-load conditions
-
Cooling operating range from 32 to 115 F ambient (down to -20 F with accessory Motormaster® V control)
-
ComfortLink™ control includes: easy to use scrolling marquee display, service diagnostics, run test capabilities, demand limit capability, compressor reverse rotation protection, and BACnet communication option.
-
Tested in accordance with UL Standard 1995 and listed by ETL and ETL, Canada
-
Meet or exceed the EER requirements of ASHRAE Standard 90.1, rated in accordance with ARI Standard 340/360
-
California Energy Commission Title 24 Compliant
Reliability Features
-
Dual electrically and mechanically independent refrigerant circuits, with coil frost protection, liquid line filter driers, and crankcase heaters standard on all models
-
Compressor protection includes high and low pressure transducers with safety cutouts
-
Circuit breaker protection for all power components
-
Cabinet made of pre-painted, galvanized steel with baked enamel finish, which meets ASTM B117 salt spray resistance test
-
Condenser-fan motors are totally enclosed with internal protection
-
Direct spark ignition, Alumagard Coated Turbo-tubular heat exchangers, and induced draft combination provide for safety and reliability
-
Reliable Integrated Gas Unit Controller (IGC) provides system evaluation & troubleshooting via on-board LED and two stage gas valves with redundant 100% shutoff
Maintenance Features
-
Large hinged service access doors
-
On-board diagnostics include refrigerant pressure sensors
-
Double wall design available
Installation Features
-
Shipped with R-410A refrigerant charge
-
Single point electrical service entry, through unit bottom or side
-
Lifting lugs
-
Factory-installed pivoting outside air hoods
Factory-Installed Options
-
Low or high gas heat options include:
-
Aluminized steel heat exchanger
-
Stainless steel heat exchanger
-
Stainless steel heat exchanger with staged gas discharge air temperature control
-
Stainless steel heat exchanger with modulating gas discharge air temperature control
-
Extended chassis for an auxiliary coil
-
Double wall construction
-
2-in. pleated filters with 4-in. field convertible filter rack
-
Bag or cartridge filters (sizes 030-070 only)
-
Outdoor air CFM station
-
Manual outside air self-closing damper
-
Modulating integrated economizer damper
-
Modulating integrated ultra-low leak economizer damper
-
Barometric relief
-
Non-modulating power exhaust (CV units only)
-
Modulating power exhaust with building pressure sensor
-
Alternate high-capacity evaporator coil (all sizes except 035)
-
High capacity power exhaust with VFD (sizes 075-100 only)
-
Return fan with VFD (sizes 075-100 only)
-
Condenser and evaporator options include:
-
All-aluminum Novation condenser and Al/Cu evaporator
-
E-coat all-aluminum Novation condenser and Al/Cu evaporator
-
Hot gas bypass
-
Controls input expansion board
-
Bypass on indoor fan motor VFD
-
GFI (ground fault interrupter) convenience outlet (powered)
-
Power terminal block
-
Non-fused disconnect
-
Airfoil supply fan (sizes 075-100 only)
-
Low outdoor sound
-
Low ambient control
-
65 kA SCCR (460V) or 25 kA SCCR (575V)
-
Digital compressor
-
BACnet communication
-
Replaceable core filter drier
-
Security grille (sizes 070-100 only)
-
Humidi-MiZer™ adaptive dehumidification system
Field-Installed Accessories
-
Liquid propane (LP) conversion kit (sizes 030-070 only)
-
2-in. and 4-in. filter kits
-
CO2 space sensor
-
Outdoor or return humidity sensor (enthalpy)
-
Condenser coil hail guard assembly
-
Controls input expansion board
-
Navigator™ display
-
Return air CO2 sensor
-
Smoke detector
-
Filter switch
-
Fan status switch
-
T55 temperature sensor
-
T56 temperature sensor
-
Space temperature sensor with CO2 override
-
Space temperature sensor set point and CO2 override
-
BACnet Communication module
-
MODBUS Carrier translator
-
LonWorks Carrier translator
-
System Pilot™ interface
-
Touch Pilot™ interface
-
14-in. roof curb
-
Motormaster V control
-
Compressor sound blankets