Compatible Hioki clamp meter or digital multimeter (DMM) is separately required.
FEATURES
Why is CAT III 2000 V capability necessary?
Recent years have seen the introduction of solar power systems and EV batteries that operate at progressively higher voltages, creating new maintenance demand. At the same time, the hazards posted by maintenance work are increasing due to use of higher voltages.
Solar installations are CAT III environments
Safety standards categorize measurement locations by measurement category ratings CAT II, CAT III, and CAT IV based on their line-to-ground rated voltage, current capacity, and transient overvoltage.
According to the standard for Photovoltaic (PV) module safety qualification (IEC 61730-1), PV modules are treated as the overvoltage category III, and an instrument categorized as Measurement Category III is required.
Solar installation voltage is increasing
Against this backdrop, measuring instruments used in maintenance of solar installations must accommodate high voltages to ensure they can be used safely. Using instruments that can accommodate the appropriate measurement category serves to protect workers and equipment from serious accidents such as electric shock and burnout.
Currently, adoption of 1500 V solar installation is growing, but instruments that can accommodate even higher voltages will be necessary in the future as larger and even more efficient systems enter into use.
Hioki developed the P2000 to support CAT III 2000 V measurement in response to the near-term prospect of such applications.
Safer measurements at solar and PV installations
DC High V Probe Mode
High voltages up to 2000 V can be safely measured when the DC High Voltage Probe P2000 is connected to the compatible Hioki clamp meter or digital multimeter (DMM).
SPECIFICATIONS
Basic specifications
Accuracy guaranteed: 1 year
Maximum input voltage (*1) |
DC 2000 V |
Maximum rated line-to-ground voltage |
1000 V (Measurement Category IV), Anticipated transient overvoltage 12000 V
2000 V (Measurement Category III), Anticipated transient overvoltage 15000 V |
Input resistance |
20 MΩ ±5.0% (between INPUT H and INPUT L, when OUTPUT terminal is open) |
Overload protection |
2200 V DC/2200 V AC (applied for 1 minute) (between INPUT H and INPUT L)
600 V DC/600 V AC (applied for 1 minute) (between OUTPUT H and OUTPUT L) |
OUTPUT terminal |
4 mm banana terminal |
Operating temperature and humidity range |
Temperature:
-25°C to 65°C (-13°F to 149°F)
Humidity:
−25°C to 40°C (−13°F to 104°F): 80% RH or less (non-condensing)
40°C to 65°C (104°F to 149°F): Linearly reduces from 80% RH or less at 40°C (104°F) to 25% RH or less at 65°C (149°F) (non-condensing) |
Storage temperature and humidity range |
-30°C to 70°C (-22°F to 158°F) 90% RH or less (non-condensing) |
Standards |
EN 61010 |
Included accessories |
Connection Cable Set L4943 ×1, Strap with buckle ×2, Strap ×1, Carrying Case C0205 ×1, Instruction Manual ×1, Operating Precautions ×1 |
Accuracy table for compatible instruments
Model |
Combined accuracy |
DT4261 |
Range 600.0 V: Combined accuracy ±0.5% rdg ±0.2 V
Range 2000 V: Combined accuracy ±0.5% rdg ±5 V |
CM4141-50
CM4371-50
CM4373-50
CM4375-50 |
Range 600.0 V: Combined accuracy ±1.0% rdg ±0.3 V
Range 2000 V: Combined accuracy ±1.0% rdg ±3 V |
DT4281
DT4282 |
Range 60.000 V: Combined accuracy ±0.8% rdg ±0.002 V (output rate 1/10)
Range 600.00 V: Combined accuracy ±0.8% rdg ±0.02 V (output rate 1/10) |
DT4252
DT4253 |
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.05 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.5 V (output rate 1/10) |
DT4255
DT4256 |
Range 60.00 V: Combined accuracy ±1.2% rdg ±0.03 V (output rate 1/10)
Range 600.0 V: Combined accuracy ±1.2% rdg ±0.3 V (output rate 1/10) |
*1:Maximum rated voltage between INPUT H and INPUT L