HI3512 is a dual-input professional pH/ORP/ISE/EC/Resistivity/TDS/NaCl/Temperature bench meter with a graphic LCD designed to provide high accuracy and ease of use both in the laboratory as well as in harsh industrial conditions. This instruments is a dual-input model measuring pH, ORP, or ISE and temperature on channel 1 and EC, Resistivity, TDS, and Salinity (utilizing an EC probe) on channel 2.

Main Features:
• Dual-input channel
- pH/mV/ISE and temperature measurements (Channel 1)
- EC/TDS, NaCl/Resistivity and temperature measurements (Channel 2)
• Up to 5 point pH calibration with 7 standard buffers and 2 custom buffers to choose from
• Up to two points EC calibration with 7 memorized standards for calibration to choose from
• Messages on the graphic LCD for an easy and accurate calibration
• Diagnostic features to alert the user when the electrode needs cleaning
• Relative mV measurements
• Log on demand up to 400 samples
• Log interval with log on stability feature up to 600 records
• Auto Hold feature, to freeze first stable reading on the LCD
• GLP, last calibration data for pH, Rel mV, ISE, EC, or NaCl
• PC interface



More Information
SKU HI3512
Product Name Dual-Input pH/ORP/ISE/EC/Resistivity/TDS/NaCl/Temperature Bench Meter with Calibration Check - HI3512
Quote Required Yes
pH Range -2.0 to 20.0 pH / -2.00 to 20.00 pH / 2.000 to 20.000 pH
pH Resolution 0.1 pH / 0.01 pH / 0.001 pH
pH Accuracy ±0.01 pH / ±0.002 pH
pH Calibration Up to 5 points / 7 Standard Buffers (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) / 2 Custom buffers
ORP Range ±2000.0 mV
ORP Resolution 0.1 mV
ORP Accuracy ±0.2 mV
ISE Range 1.00x10-7 to 9.99x1010 conc.
ISE Resolution 3 digits 0.01, 0.1, 1, 10 conc.
ISE Accuracy ±0.5% of reading (monovalent ions) / ±1% of reading (divalent ions)
ISE Calibration Up to 5 points / 6 standards (0.1, 1, 10, 100, 1000, 10000 ppm)
Temperature Channel 1 Range -20.0 to 120.0 °C (-4.0 to 248.0 °F)
Temperature Channel 1 Resolution 0.1 °C (0.1 °F)
Temperature Channel 1 Accuracy ±0.2 °C (±0.4 °F) (excluding probe error)
Rel mV offset range ±2000 mV
Slope calibration From 80 to 110%
pH Temperature Compensation Manual / Automatic
Electrode Hanna BNC connection pH / ORP / ISE electrodes
Temperature Probe RCA connection / Recommended option
EC Range 0 to 400 mS/cm (shows values up to 1000 mS/cm) / Actual conductivity 1000 mS/cm
0.001 to 9.999 μS/cm
10.00 to 99.99 μS/cm
100.0 to 999.9 μS/cm
1.000 to 9.999 mS/cm
10.00 to 99.99 mS/cm
100.0 to 999.9 mS/cm
1000 mS/cm (autoranging)
EC Resolution 0.001 μS/cm
0.01 μS/cm
0.1 μS/cm
0.001 mS/cm
0.01 mS/cm
0.1 mS/cm
1 mS/cm
EC Accuracy ±1% of reading (±0.01 µS/cm or 1 digit, whichever is greater) excluding probe error
EC Calibration Up to 2 points / 7 Standards (0.00 µS/cm, 1.413 mS/cm, 5.00 mS/cm, 12.88 mS/cm, 111.8 mS/cm)
Resistivity Resolution 1.0 to 99.9 ohms
100 to 999 ohms
1.00 to 9.99 Kohms
10.0 to 99.9 Kohms
100 to 999 Kohms
1.00 to 9.99 Mohms
10.0 to 100.0 Mohms (autoranging)
Resistivity Accuracy 0.1 ohm
1 ohm
0.01 Kohms
0.1 Kohms
1 Kohms
0.01 Mohms
0.1 Mohms
Resistivity Calibration ±1% of reading (±10 ohms or 1 digit, whichever is greater) excluding probe error
TDS Range 0.000 to 9.999 ppm
10.00 to 99.99 ppm
100.0 to 999.9 ppm
1.000 to 9.999 g/L
10.00 to 99.99 g/L
100.0 to 400.0 g/L (autoranging)
TDS Resolution 0.001 ppm, 0.01 ppm, 0.1 ppm, / 0.001 g/L, 0.01 g/L, 0.1 g/L
TDS Accuracy ±1% of reading (±0.05 ppm or 1 digit, whichever is greater) excluding probe error
TDS Factor 0.40 to 1.00
Salinity Range % NaCL: 0.0 to 400.0 %
Salinity Resolution 0.1%
Salinity Accuracy ±1% of reading (excluding probe error)
Temperature Channel 2 Range -20.0 to 120.0 °C (-4.0 to 248.0 °F)
Temperature Channel 2 Resolution 0.1 °C (0.1 °F)
Temperature Channel 2 Accuracy ±0.2 °C (±0.4 °F) (excluding probe error)
NaCl Calibration Max. 1 point only (with HI7073 standard)
EC probe DIN connection / Recommended option
Temperature Source Automatic / Manual
EC Temperature Compensation NoTC, MTC, ATC
Reference temperature 15, 20, 25 °C
Log on demand 400 samples
Lot logging 5, 10, 30 seconds / 1, 2, 5, 10, 15, 30, 60, 120, 180 minutes, AutoEnd (maximum 600 samples)
Environment 0 to 50 °C (32 to 122 °F) / max. RH 55% non-condensing
Power Supply 12 Vdc power adapter
PC Interface opto-isolated USB
Dimensions 235 x 207 x 110 mm (9.2 x 8.14 x 4.33 in.)
Weight 1.8 Kg (4.1 lbs)