Benchtop Grating Spectrophotometer BK-GS6060

Benchtop Grating Spectrophotometer BK-GS6060

分类: Spectrophotometer 当前有货
欲了解更多详情,请游览我们的官方网站 lnbtec.com

详情

Features;

1, High configuration of hardware: 7 inches TFT Color Capacitive Touch screen

Display; Concave Grating.

2, Double Array 256 Image Element CMOS Sensor; Long life-span stable LED, UV LED and xenon lamp.

3, With reflective and transmissive spectrum, accurate Lab value, good to calculate color formula and do precise color transmission.

4, Auto identify measuring aperture. Freely switchable between 4 measuring apertures: φ25.4mm/15mm/8mm/4mm. Users also can customize apertures.

5, Built-in temperature sensor to monitor and compensate the measuring temperature to ensure the measurement more precision.

6, Wavelength range 360nm ~780nm. Built-in 400nm cut off/420nm cut off/460nm cut off (only xenon lamp edition), more professional in UV measurement.

7, Independent light source detector, continuously monitor the condition of light sources to ensure the light source reliable.

8, Multiple measurement modes: Quality Management Mode, Sample Mode; Meet more users’ requirement.

9.Multiple accessories, sample holders, fixation clamp, suitable to more working condition.

10, Big capacity data storage, for 20000 pieces test result.

11, Built-in camera locating.

12, More powerful extended functions at the PC software.

Application

BK-GS6060 benchtop spectrophotometer is used to do precise color analysis and transmission in laboratories. It can be widely applied in different industries, such as plastics, electronics, paint and ink, printing, garments, leather, paper, auto, medical, cosmetics, food, science institutes, laboratories.
 

Technical Specification:

Model

BK-GS6060

Optical Geometry

Reflect: di:8°, de:8°(diffused illumination, 8-degree viewing angle) ;         
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source
Transmittance: di:0°, de:0° (diffuse illumination: 0° viewing) ;                     
SCI (specular component included)/SCE (specular component excluded) ; Include UV / excluded UV light source;
Haze(ASTM D1003),
Conforms to CIE No.15,GB/T 3978,GB 2893,GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7

Application

It is used for accurate analysis and transmission of laboratory color.     Apply in paints, inks, textiles, garments, printing and dyeing, printing etc industries for color transfer and quality control.

Integrating Sphere Size

Φ154mm

Light Source

360 nm to 780 nm, Combined LED Light, 400nm cut-off light source,420nm Cut-off light source, UV Lamp

Spectrophotometric Mode

Concave Grating

Sensor

256 Image Element Double Array CMOS Image Sensor

Wavelength Range

360-780nm

Wavelength Interval

10nm

Semi-band Width

10nm

Measured Reflectance Range

0-200%

Measuring Aperture

Reflective: Φ30mm/Φ25.4mm, Φ18mm/Φ15mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm;
Transmissive: Φ30mm/Φ25.4mm;                    

Specular Component

Reflectance: SCI&SCE / Transmittance: SCI&SCE

Color Space

CIE LAB, XYZ, Yxy, LCh, CIE LUV, Musell, s-RGB, HunterLab, βxy, DIN

Color Difference Formula

ΔE * ab, ΔE * uv, ΔE * 94, ΔE * cmc(2:1), ΔE * cmc(1:1) , ΔE * 00 , DINΔE 99 ,ΔE (Hunter),

Other Colorimetric Index

WI (ASTM E313, CIE/ISO, AATCC, Hunter,

YI (ASTM D1925, ASTM 313),TI (ASTM E313, CIE/ISO),

MI (Metamerism Index), Staining Fastness,

Color Fastness, Color Strength, Opacity,

Gardner Index, Pt-Co Index, 555 Index

Observer Angle

2°/10°

Illuminant

D65,A,C,D50,D55,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12

Displayed Data

Spectrogram/Values, Samples Chromaticity Values, Color Difference Values/Graph, PASS/FAIL Result, Color Offset

Measuring Time

About 2.4s (Measure SCI & SCE about 5s)

Repeatability

Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.04% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.01 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)                                                                                        Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.05% (400 nm to 700 nm: within 0.04%)
Chromaticity value:Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)

Inter-instrument Error

Φ25.4mm/SCI, Within ΔE*ab 0.12 (Average for 12 BCRA Series II color tiles)

Illuminant Life Span

5 years, more than 3 million times measurements

Display

7-inch TFT color LCD, Capacitive Touch Screen

Data Port

USB & Bluetooth

Data Storage

Standard 5000 Pcs, Sample 40000 Pcs (One PCS can include both SCI and SCE)

Language

Chinese, English

Operating Environment

0~40℃, 0~85%RH (no condensing), Altitude < 2000m

Storage Environment

-20~50℃, 0~85%RH (no condensing)

Standard Accessory

White and Black Calibration Board, Checking Green Board, Sample Holder,∮4mm, ∮8mm, ∮15mm, ∮25.4mm Aperture, Power Adapter, USB Cable, User Guide, PC Software

Optional Accessory

Micro printer, Transmissive Test Clamp Component

Power Supply

DC 24V, 3A; Power adapter: 110~230V 50/60HZ

External Size(L*W*H)

370*300*200mm

Weight

9.6kg

Package Size (W* D*H)

350*470*520mm

Gross Weight

18kg

更多 LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. 相关资料
LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.
LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. Measuring Equipment Wholesaler Malaysia, Coating Instruments Supplier Penang, Hardware Tools Supply Kuala Lumpur (KL), Selangor ~ LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.