Description

WEIGHING INDICATOR
 

Product outline

New Standard for Weighing Indicator!
Recordable Data on SD Card, Vibration Resistant, Drip & Dustproof Structure

 

FC1000 is the weighing indicator with various features such as the white LCD main and sub display, dust and drip protection (Equivalent to IP65), accumulation function, data recording on SD Card, and high-speed A/D conversion rate of 1.2kHz.
\

 

SD card slot

SDcard

 You can write and read setting parameters from SD cards,

 while recording weighing results & data when abnormalities occur.

 

icon Calibration value & Error logs are automatically recorded

 You can identify the indications of faulty load cells and

 replacement timing.

 Date & time of errors occurred can be displayed,

 as well as the record of how the errors are made

 (through key control, communication, I/O, etc).

 

icon Data recording of weighing results

 Monitor management of raw material, equipment operation rate

 and so on.

 Long-term trend can be observed as well.

 

icon Restore setting parameters with just one touch

 0鸜ou can copy setting parameters to another replaced FC1000.

 0鸐ultiple FC1000s can use the exact same settings.

 0鸜ou can restore the initial setting when you first install FC1000.

  (It will be saved as initial value separately from the

  setting parameters).


 

Depth of 99mm

 Miniaturization of control panel & panel space saving.


 

High performance filter & Auto filter adjustment

 With combination of low pass filter (0.1~300Hz)

 which corresponds to various vibration and moving average filter (OFF, 2~512)

 that is effective for periodic vibration,

 automatic searching for optimal value with accuracy and stability can be achieved.

 (You can manually adjust settings too).

 

 

Auto filter adjustment

 

Minus compensation

 High-pressure liquid filling & powder feeding can be done.

 

icon

 

 

Equivalent to IP65 protection

 By placing the rubber seal when mounting on the panel,

 the front panel can be protected from moisture and dust damage.


 

High sampling rate & resolution

 High performance digital low-pass filter can be adjusted at 0.1Hz increment. As it is resistant to vibration,

 measurement can be performed quickly and precisely.


 

Load cell signal level display (-2.51mV/V to 5.1mV/V)

 The output signal level of load cell can be displayed in mV/V for monitor purpose.

 Malfunction indicator or faulty sensor can be differentiated easily.


 

Total weight control function

 The batch weighing with a low capacity scale enables the fast and accurate measurement of

 larger total weight.
 

 

Total weight control function


 

 

Bright white LCD display with the useful 20 digits sub display.

 

Bright white LCD display with the useful 20 digits sub display.

 

 The sub display can be used to show the cumulative weight, code/preset number, etc….


 

 

6 digit display

 24 bit A/D convertor enables 6 digit display.

 

Memory for 32 weight settings

 32 different weight settings can be saved in the memory and selected through I/O or interface.

 Batch weighing can be performed easily.


 

Equivalent input calibration

 Theoretical calibration can be performed easily by registering

 the capacity and rated output of load cells.


 

Multipoint calibration (linearization)

 Three additional points can be defined in the middle between zero and span for better linearity.

 Even though the scale has poor linearity, it can be corrected to be a highly accurate scale.

 

 

Multipoint calibration (linearization)


 

 

Structure of product code

Structure of product code
 

External dimension

External dimension

 

Specifications

Analog
Excitation voltage DC5V±5% Output current:90mA
Remote sense type (Up to 6 350Ω load cells can be connected in parallel)
Signal input range -2.5 to +5.1mV/V
Zero adjustment range Automatic adjustment by digital processing -2.5 to +2.0mV/V
Span adjustment range

Automatic adjustment by digital processing 0.02 to +3.0mV/V

Gain correction Up to three point multi-point calibration is possible using linearization function
Min. input sensitivity 0.15μV/count
Accuracy Non-linearity: within 0.01%FS
Zero drift: 0.0002%FS/℃ Typ
Gain drift: 1ppm/℃ Typ
Filter Digital low-pass filter 0.1 to 300.0 Hz
Moving average filter OFF, 2 to 512 times
A/D converter Speed: 300 times/sec, 1200 times/sec
Resolution: 24bit binary
 
Display
Display Unit 7-segment LCD display
Main display: 8 digit(14.4mm character height),
sub-display: 20 digit (4.3mm character height)
Display value 5 digit sign: negative display at the highest digit (Up to 6 digits)
Unit None / kg / g / t / lb / N
Decimal point 0、0.0、0.00、0.000
Weight errors ''LOAD'': sensor signal level is above the signal input range, ''-LOAD'': the sensor signal level is below the signal input range, ''OFL1'': the Net weight is over the limit, ''OFL3'': the GROSS weight is over the limit
Display frequency 1, 3, 6, 13 or 25 times/sec.
Status display SP1/SP2/SP3/COMPLETE/TARE ON/NET/OUT1/OUT2
 
Setting
Setting method By operating the membrane keys or through interface
Memory of set value Default settings: stored in NOV.RAM(non-volatile RAM)
Time: backed up by lithium battery
Other setting values: stored in F-RAM(non-volatile RAM)
Protection of set value Settings can be protected with the software LOCK
Setting item - Comparison Inhibit Time 1 / Judging Time / Complete Output Time / Compensation Feeding Time / AZ Times / Judging Times / Auto Free Fall Compensation Limit / Comparison Inhibit Time 2 / Tare Weight
- Weighing Function 1 / Weighing Function 2 / Weighing Function 3 / Sequence Mode / Lock Function Keys / Discharge Time / Motion Detection(Time & Range) / Zero Tracking Time / Zero Tracking Range
- Weighing Function 1 / Weighing Function 2 / Weighing Function 3 / Sequence Mode / Lock Function Keys / Discharge Time / Motion Detection(Time & Range) / Zero Tracking Time / Zero Tracking Range
- Balance Weight Value / Minimum Scale Division / Net Over / Gross Over / DZ Regulation / Function Selection / Gravitational Acceleration / Sampling Speed / Sub display Selection
- D/A Output Mode / D/A Zero Output Weight / D/A Full Scale / RS-232C / RS-485 Setting / ID Number / Delay Time / CC-Link Number / CC-Link Station / Level Signal Priority
- Input Selection 1 / Input Selection 2 / Output Selection 1 / Output Selection 2 / Output Selection 3 / Status Display Selection / Automatic Filter Adjustment / Digital Low Pass Filter / Moving Average Filter
- Batch Count / SP0 / Total Weight Comparison Selection / Target Total Weight (Upper 4 digit) / Target Total Weight (Lower 5 digit) / Total Weight Set Point (Upper 4 digit) / Total Weight Set Point (Lower 5 digit)
- Read Settings from the SD Card / Write the Settings on the SD Card / Protect Settings / Extended Function Selection 1 / Extended Function Selection2 / Total weight control function
- Average Weight / Max. Value / General Standard Deviation / Data Count / Latest Data / Max.-Min. / Option Board Confirmation
- Span Calibration / Equivalent Input Span Calibration / Equivalent Input Zero Calibration / Linearize Calibration1 / Linearization Calibration2 / Linearization Calibration3 / Linearization Calibration ON/OFF / Calibration Point Confirmation / Password / Zero Calibration
 
External signal
Output signal(12) Selectable/configurable
Open collector output
Vceo=30V, Ic=120mA
Input signal(8) Selectable/configurable
Non-voltage contact input
(internal circuit power supply voltage 12V)
 
Interface
·SI/F interface
·SD card slot
·Select either RS-232C or RS-485 interface
·BCD parallel data output interface (Option)
·D/A converter current output (Option)
·CC-Link interface (option)
 
General specification
Power supply voltage AC100 to 240V (+10% -15%) (free power source 50/60Hz)
Power consumption 5W typ
Operating conditions Temperature Operating temperature range: -10 to +50℃
Storage temperature range: -20 to +60℃
Humidity 85%RH or less(non-condensing)
Dimensions 144(W) × 72(H) × 109(D) mm (excluding the projections)
Weight Approx. 850g
 
Attachment
·AC input cord (nominal rating 125V) 3m···1
·FCN series I/O connector (with cover)···1
·Load cell input connector···1
·Operating tool···1
·Jumper cable···2
·SD card (1GB)···1
·Rubber seal for dust & drop-proof protection···1
·Quick manual···1
·BCD output connector (when BCO option is selected)···1
·D/A converter connector (when DAC option is selected)···1
·CC-Link connector (when CC-Link option is selected)···1