Description
BGD 155/S series professional viscometersare newest full touch screen products which are developed from Biuged BGD 155 viscometers. Add more functions as below on the base of BGD 155 viscometrs.
Main Technical Parameters
Ordering Information → Parameters ↓ |
BGD 155/1S |
BGD 155/2S |
BGD 155/3S |
Measurement Range (mPa.s) |
10-600,000(600K) |
10-6,000,000(6M) |
100-80,000,000(80M) |
R.P.M (per min) |
1-60 |
0.1-100(infinitely variable speed) |
|
Rotor Amount |
No.1, No.2, No 3, No 4 are standard configurations (#0 is optional) |
||
Measurement Accuracy |
±1.0 % (of the full range) |
||
Repeatability |
±0.5 % |
||
Power Supply |
Power Supply Adapter:100V~240V/50Hz |
||
Optional Accessories |
BGD 1601---Low viscosity adapter (the No.0 rotor) BGD 1602---Small sample adapter (comes with NO.21、NO.27、NO.28、NO.29 rotors) BGD 1603---Mini single color printer BGD 1607---Viscometer data collection and graphing software |
NOTE:
1. If customer needs the small sample adapter, the machine would come with NO.21、NO.27、NO.28、NO.29 rotors(the normal rotors are No.1, No.2, No.3, No.4). Please clarify before ordering if extra rotors are required.
2. If selected the small sample adapter, the measurement range would be as below:
BGD 155/1S:10-100,000 (100K)mPa.s
BGD 155/2S:10-1,000,000 (1M)mPa.s
BGD 155/3S:50-10,000,000(10M) mPa.s
THD Series---Low Temperature Thermostatic Bath
BGD 1600---Standard Oil(500ml)
BGD 1601---Low Viscosity Adapter(The 0th rotor and can measure 1.0 mPa.s sample)
BGD 1602---Small Sample Adapter(It’s specially designed for customers with small samples and requires only a quantity as small as 5~18ml;Sample cup is easily cleaned, installed, removed, and observed;Accurate data of shear rate and shear stress can be obtained for a minute analysis of the fluid characteristics of the sample;One-off sample cups are available)
BGD 1603---Mini Single Color Printer
BGD 1604---RTD Thermometer(-20℃~120℃)
BGD 1605---Thermoses(It has been designed to accurately measure the viscosity of heated oil, paraffin, asphalt emulsions, medicine, high polymer and similar liquid materials at high temperatures. It allows control of a sample’s temperature at a range of room temperature +300℃. It can program the intelligent thermostat and ensures its temperature fluctuation within 0.1℃. Sample dosage is as small as 10ml, and one-off sample cups are available. Standard type of SC4 spindle can be applied, which is easy to use)
BGD 1607---BGD 155 Viscometer data collection and graphing software(Automated data collection; resulting in viscometer graph, and recording measuring data each time;Allowing comparison of at most 10 history data;Output Excel documents)
More detail about LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.