Features | Explanations |
LCD Languages | English / Turkish |
Entries | 13x Configurable digital inputs, 4x resistive configurable inputs, Magnetic pickup and charge alternator (D+(WL) inputs) |
Outputs |
Busbar Contactor Output 8A@250Vac Mains Contactor Output 8A@250Vac Configurable Output-1 with DC supply 15A Configurable Output-2 with DC supply 15A Configurable Output-3,4,5,6,7,8,9 with DC supply 1A |
Load Current Measurement |
3 phase generator current measurement, 1 phase network current measurement 3-300 Vac Phase-Neutral, 5-99.9 Hz. Accuracy: 1% of scale Resolution: 1V, Harmonic: up to 11th harmonic. |
Voltage Measurement |
3 phase network, 3 phase generator 3-300 Vac Phase-Neutral, 5-99.9 Hz. Accuracy: 1% of scale Resolution: 1V, Harmonic: up to 11th harmonic. |
Physical Features | |
Dimensions | 276mm x 189mm x 45mm. |
Protection Class | Front IP65 |
Working Range | |
Supply | 8...32Vdc, maximum power consumption 360mA |
Resistive Analog Inputs | 0 ... 1300 ohms, accuracy: 1%FS, resolution: 1 ohm |
Cabin Temperature Measurement | |
Storage / Operating Temperature | -40°C ... +80°C / -20°C ... +70°C |
Expansion Modules | |
Internal |
USB programming and communication port, CanBus communication with J1939 ECU, Ethernet, RS485. |
GPRS | Optional |
Embedded WEB server | Optional |
Serial ModBus | |
Quality Certificates | CE, GOST-R |