Tenmars TM-1016 AC-HVAC Clamp Phase

Tenmars TM-1016 AC-HVAC Clamp Phase

Category: AC-HVAC Clamp Phase Available
For more information, visit our official website at mtmpre.com.my

Description

TM-1016  AC-HVAC Clamp Phase


 
This apparatus conforms to safety standard EN 61010

 

Application

It can be used for CURRENT, VOLTAGE and FREQUENCY measurements on installations of surge voltage category III up to 600 V, voltage between Phase and Earth (fixed installations) and for current measures up to 400A.

 

Features

The apparatus can perform the following measurements:

Specifications


CHARACTERISTICS SPECIFICATIONS(23℃±5℃, with RH< 75%RH )
DC µA (Auto/Manual)
Range Resolution Accuracy Burden Voltage Overload Protection
400µA 0.1µA ±(1.0%+2) 500uV/uA 0.2A/250V Fuse
4000µA 1µA
 
AC µA (Auto/Manual)
Range Resolution Accuracy
50Hz~60 Hz
Burden Voltage Overload Protection
400µA 0.1µA ±(1.2%+3) 500µV/µA 0.2A/250V Fuse
4000µA 1µA
 
ACA (Auto/Manual)
Range Resolution Accuracy
50Hz~60 Hz
Overload Protection
40A 0.01A ±(2.0%+10) 600A rms (60 second)
400A 0.1A ±(1.5%+10)
 
DCV (Auto/Manual)
Range Resolution Accuracy Input Impedance Overload Protection
4V 1mV ±(0.8%+2) 11MΩ DC/AC660V rms
40V 10mV 10MΩ
400V 100mV
600V 1V ±(1.0%+2)
 
ACV (Auto/Manual)
Range Resolution Accuracy 50Hz~500 Hz Input Impedance Overload Protection
4V 1mV ±(1.0%+3) 11MΩ DC/AC660V rms
40V 10mV 10MΩ
400V 100mV
600V 1V ±(1.2%+3)
 
Resistance (Auto/Manual)
Range Resolution Accuracy Max. Open Voltage Overload Protection
400!& 0.1!& ±(0.8%+5) about -1.5VDC DC/AC600V rms
(60Second)
4K!& 1!& ±(0.8%+2) About-0.45VDC
40K!& 10!&
400K!& 100!&
4M!& 1K!&
40M!& 10K!& ±(3%+2)
 
Continuity Test
Range Buzzer Max. Open Voltage Overload Protection
below 25 About-1.5VDC 600V rms
 
Capacitance (Auto/Manual)
Range Resolution Accuracy Overload Protection
4nF 1pF ±(3%+10) DC/AC600V rms
(60Second)
40nF 10pF
400nF 100PF
4µF 1nF
40µF 10nF
400µF 100nF
4mF 1µF ±(5%+10)
 
Temperature:optional temp.probe:K(CA) type.
Range Resolution Accuracy
°C 1°C -50°C~ 0°C±(1.8%+2°C) 
0°C~ 500°C±(1.0%+2°C) 
500°C~ 1200°C±(1.8%+2°C)
°F 1°F -58°F~ 32°F±(1.8%+3°F) 
32°F~ 932°F±(1.0%+3°F) 
932°F~ 1999°F±(1.8%+3°F)
The tolerance of temp. Probe excluded.
Max.input voltage for thermocouple:DC60V,AC24V

 


 

More detail about MTM Precision Sdn Bhd
MTM Precision Sdn Bhd
MTM Precision Sdn Bhd Surveying Instruments Selangor, GPS Systems Supply Kuala Lumpur (KL), Total Stations Supplier Malaysia ~ MTM Precision Sdn Bhd
Contact Us flagMalaysia