Description
TM-1017 400A True-RMS AC Power Clamp Meter+ Phase
This apparatus conforms to safety standard EN 61010
Application
It can be used for CURRENT measurements on installations of over voltage category III up to 600V (voltage between phase and earth) and for VOLTAGE and FREQUENCY measurements on installations of over voltage category III up to 600V (voltage between terminals and between phase and earth).
Features
The apparatus can perform the following measurements:
- AC voltage (VAC) with TRMS conversion mode.
- DC voltage (VDC).
- AC current (IAC) with TRMS conversion mode.
- Harmonic AC voltage (from DC to 24h components)
- Harmonic AC current (from 1st to 24th components).
- Frequency with input test leads.
- Frequency with clamp jaws.
- Resistance.
- Continuity test.
- Phase rotation with only one test lead.
- Active, reactive, apparent power and power factor measure on single-phase systems.
- Active, reactive, apparent power and power factor measure on balanced three phase systems.
- Active, reactive, apparent energy measurements on single-phase systems.
- Active, reactive, apparent energy measurements on balanced three phase systems.
Specifications
- Display:4 dgt LCD with maximum reading 9999 units plus decimal point and sign
- Sample rate:64 samples in 20ms
- Conversion mode:TRMS
- Jaws opening:30mm
- Max conductor size:30mm
- Dimension: 205mm(L)x64mm(W)x39mm(H).
- Weight:about 280g. (Including battery)
CHARACTERISTICS SPECIFICATIONS(23℃±5℃, below 75%RH )
DC Voltage |
Range |
Resolution |
Accuracy |
Input impedance |
0~599.9V |
0.1V |
±(1.0%+3dgt) |
1M!& |
AC Voltage(TRMS) |
Range |
Resolution |
Accuracy |
Input impedance |
40~200Hz |
200~400Hz |
1.6~599.9V |
0.1V |
±(1.0%rdg+3dgt) |
±(5.0%rdg+3dgt) |
1M!& |
Max. Crest factor = 1.41 |
MAX / MIN / AVG / PEAK AC/DC Voltage |
Function |
Range |
Resolution |
Accuracy |
Response time |
MAX,MIN,AVG |
10÷599.9V |
0.1V |
±(5.0%rdg+10dgt) |
500ms |
PEAK |
10÷ 850V |
1V |
±(5.0%rdg+10dgt) |
1ms |
AC Current (TRMS) |
Range |
Resolution |
Accuracy |
Overload protection |
40÷200Hz |
200÷400Hz |
0.0~399.9V |
0.1A |
±(1.0%rdg+3dgt) |
±(5.0%rdg+3dgt) |
600A RMS |
Max. Crest factor = 2 |
MAX / MIN / AVG / PEAK AC Current |
Function |
Range |
Resolution |
Accuracy |
Response time |
MAX,MIN,AVG |
1.0~399.9V |
0.1V |
±(5.0%rdg+10dgt) |
500ms |
PEAK |
10~800V |
1V |
±(5.0%rdg+10dgt) |
1ms |
Resistance and Continuity test |
Range |
Resolution |
Accuracy |
Overload protection |
0.0~499.9!& |
0.1!& |
±(1.0%rdg+5dgt) |
600V AC/DC RMS |
500~999!& |
1!& |
1000~1999!& |
3!& |
Instrument emits a buzzer for R<40!& |
Frequency (with test leads/ with jaws) |
Range |
Resolution |
Accuracy |
Overload protection |
40.0~399.9Hz |
0.1Hz |
±(0.5%rdg+1dgt) |
600V RMS / 600A RMS |
Voltage range for frequency measure, with test leads: 0.5 - 600V, with jaws: 0.5 - 400V |
Voltage and current harmonics |
Harmonic order |
Resolution [V], [A] |
Accuracy |
1~15 |
0.1 |
±(10.0%rdg+5dgt) |
16~25 |
0.1 |
±(15.0%rdg+5dgt) |
ccuracy defined for: voltage≥1.6V, current≥2A |
Power factor≥ |
Range |
Resolution |
Accuracy |
0.20~1.00 |
0.01 |
±3° |
Accuracy defined for: sine wave, voltage 230 - 400V, current≥2A, freq. 50-60Hz |
Active power, Reactive power, Apparent power |
Range
[kW],[kVAR],[kVA] |
Resolution
[kW],[kVAR],[kVA] |
Accuracy |
0.00~99.99 |
0.01 |
±(3.5% rdg+3dgt) |
100.0~999.9 |
0.1 |
Accuracy defined for: sine wave, voltage 230- 400V, current≥1A, freq. 50-60Hz, Pf: 0.8i - 0.8c |
Phase sequence and phase coincidence |
Range |
Frequency range |
Input impedance |
Overload
protection |
50~600V |
40-69Hz |
1M!& |
600V RMS |
MAX / MIN / AVG Resistance and Continuity test |
Range |
Resolution |
Accuracy |
Tempo di risposta |
0.0~499.9!& |
0.1!& |
±(1.0%rdg+5dgt) |
1s |
500~999!& |
1!& |
1000~1999!& |
3!& |
Instrument emits a buzzer for R<40!& |
MAX / MIN / AVG Frequency (with test leads/ with jaws) |
Range |
Resolution |
Accuracy |
Tempo di risposta |
40.0~399.9Hz |
0.1Hz |
±(0.5%rdg+1dgt) |
1s |
Max"f/"t =0.5Hz/s |
MAX / MIN / AVG Active power,
Reactive power, Apparent power |
Range [kW],[kVAR],[kVA] |
Resolution [kW],[kVAR],[kVA] |
Accuracy |
Tempo di risposta |
0.1~99.99 |
0.01 |
±(3.5%rdg+3dgt) |
1s |
100.0~999.9 |
0.1 |
Accuracy defined for: sine wave, voltage 230÷400V, current≥1A, freq. 50-60Hz, Pf: 0.8i÷0.8c |
MAX / MIN / AVG Power factor |
Range |
Resolution |
Accuracy |
Response time |
0.20~1.00 |
0.01 |
±3° |
1s |
Accuracy defined for: sine wave, voltage 230 - 400V, current≥2A, freq. 50-60Hz |