The HI9147 is a rugged, water-resistant dissolved oxygen (DO) meter designed to provide precision and accuracy under harsh environmental conditions. The meter features a manual one point calibration, automatic temperature compensation, and salinity and altitude compensation. The HI9147 supplied with a galvanic, HDPE membrane caps, electrolyte fill solution, a protective shield, and sturdy carrying case.
Details
Dissolved oxygen is a commonly measured parameter in aquaculture, wastewater treatment, environmental studies, and wine analysis. The HI9147 is a rugged, water-resistant dissolved oxygen (DO) meter designed to provide precision and accuracy under harsh environmental conditions. The meter features a manual one point calibration, automatic temperature compensation, and salinity and altitude compensation. The HI9147 includes a galvanic probe with replaceable high density polyethylene (HDPE) membrane caps and a protective shield.The salinity compensation allows for the determination of dissolved oxygen even in salty waters making this an ideal meter for aquaculture applications. The HI9147 is supplied complete and ready to use.
Features at a Glance
Replaceable Membrane Caps - The pretensioned high density polyethylene (HDPE) membranes employ a screw cap design that can be changed quickly by simply filling with the HI7042 electrolyte fill solution and screwing onto the DO probe.
Galvanic Measuring System - The meter and probe use galvanic sensor technology where the electrodes’ potential difference drives the reaction, requiring no external voltage. The probe is comprised of a silver cathode and zinc anode in an electrolyte solution held in place over the surfaces of the electrodes by a polymer membrane. Oxygen diffuses across the membrane and the system establishes a current proportional to the concentration of dissolved oxygen present.
Automatic Temperature Compensation - All readings are automatically compensated for temperature variations with a high accuracy, built in linearized thermistor temperature sensor behind a stainless steel cover.
Altitude Compensation - The HI9147 allows for altitude compensation for up to 4000 meters with a 100 meter resolution.
Salinity Compensation - Salinity compensation is adjustable from 0 to 51 g/L (ppt) with a 1 g/L resolution for the measurement of DO is brackish and seawater.
Backlit LCD - The HI9147 has a display with a backlight for easy viewing of readings in poor lighting conditions.
Specifications
DO Range | 0.00 to 50.00 ppm (mg/L); 0.0 to 600.0% saturation |
DO Resolution | 0.1 mg/L (ppm); 1% saturation |
DO Accuracy | ±1% of reading |
DO Calibration | manual, in saturated air |
Temperature Range | 0.0 to 50.0°C / 32.0 to 122.0°F |
Temperature Resolution | 0.1°C; 1°F |
Temperature Accuracy | ±0.2°C; ±1°F (excluding probe error) |
Temperature Compensation | automatic from 0 to 50°C (32 to 122°F) |
Altitude Compensation | 0 to 4000 m (resolution 100 m) |
Salinity Compenstaion | 0 to 51 g/L (ppt) (1 g/L resolution) |
Electrode/Probe | galvanic DO probe, internal temperature sensor, DIN connector |
Battery Type/Life | 1.5V AAA (3) / approximately 1000 hours of continuous use without backlight |
Environment | 0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions | 185 x 72 x 36 mm (7.3 x 2.8 x 1.4”) |
Weight | 450 g (15.9 oz.) |
Ordering Information | HI9147 is supplied complete with HI76409 probe, HI76409A/P pre-formed HDPE DO membranes (2), HI7042S electrolyte solution (30 mL), batteries, instructions and rugged carrying case |
Warranty | 2 years (probe 6 months) |