Description
Designed for active leaks with a pressure boundary up to 100 psi, the LeakStop™ system is a mechanical clamping solution consisting of a sized Fiber Reinforced Plastic (FRP) shell lined with a gasket and secured by metallic compression bands. The LeakStop™ system is available with gaskets not only for standard service, but also for chemical service applications. The system provides complete fit-up integrity between the sealing gasket pad and the pipe, creating a compression seal to stop the leak. Temperature-rated to 250° F, the system installs quickly with minimal down time.
Technical Specs
Mechanical Properties Attribute Tensile Strength Method ASTM D 3039 Value 54,000 psi Attribute Compression Strength Method ASTM D 695 Value 28,500 psi Attribute Barcol Hardness Method ASTM D 2583 Value 53 |
Thermal Properties Attribute Max. Operating Temperature Value 250 °F (121 °C) Attrbute Max. Application Temperature Value 250 °F (121 °C) |
System Properties Attribute Wear Pad Thickness Value 0.25 inches (6.35 mm) |
1. Position and Secure LeakStop™ Pad Position the LeakStop™ pad over the defect. Secure the stainless steel banding clamp over the pad center and tighten the band until the leak stops. |
|
2. Position and Secure Remaining Bands Position and tighten each band using the tensioning tool. Media blast or grind the remaining repair area to create a clean anchor patter, then solvent wipe the surface. |
|
3. Apply Load Transfer Putty to Band Clamps Knead putty until uniform in color. Then apply the putty to the band clips using a “tented profile.” |
|
4. Apply Epoxy Paste Mix and apply a 30 mil coating of epoxy paste. Allow the paste to thicken for 10-15 minutes – a “peanut butter” consistency is desired. |
|
5. Apply Pipe Wrap® and Topcoat Apply provided PipeWrap® using the cigar wrap method. A topcoat may be applied after two hours. |