The HI9829 is a waterproof portable logging multiparameter meter that monitors up to 14 different water quality parameters. The microprocessor based multi-sensor probe allows for the measurement of key parameters including pH, ORP, conductivity, dissolved oxygen, turbidity, ammonium, chloride, nitrate, and temperature. The probe transmits readings digitally with options to log data while disconnected from the meter. An optional GPS provides location tracking of measurements. The complete system is simple to setup and easy to use. The HI9829 is highly customizable and supplied with all necessary accessories, packaged in a durable carrying case.
The HI7609829 (basic) and HI7629829 (logging) are multiparameter probes for use with the HI9829 portable meter. It is an option to choose which probe will be supplied with the HI9829. By default the HI9829 and corresponding probe will be supplied with a pH/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with a turbidity/conductivity sensor.
*All channels logging at 10 minute intervals with no averaging
Waterproof Protection – The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.
Backlit Dot Matrix LCD Display – The HI9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.
Intuitive Keypad – The fitted rubber keypad has dedicated keys for power, backlight, up/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.
Dedicated Help Key – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration. The help information displayed is relative to the setting/option being viewed.
Auto-sensor Recognition - The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.
Automatic temperature compensation – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.
Automatic Barometric Pressure Compensation – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.
Quick Calibration – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.
GLP Data – HI9829 includes a GLP feature thatallows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers/standards used for calibration, and slope characteristics.
Data Logging – The HI9829 allows users to store up to 44,000 continuous or log-on-demand samples with logging intervals from one second to three hours.
Graphing Capability - Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.
PC Connectivity – Logged data can be transferred to a Windows compatible PC with the included HI7698291 USB adapter and HI929829 software.
Long Battery Life - The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C “ NiMH rechargeable batteries that provide up to 140 hours of battery life*
Rugged thermoformed carrying case – The HI9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.
* Without GPS or turbidity measurements
GPS Option
The meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data.
Quick Calibration
The quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps.
Graphing Capability
Trend graphing with sample date and time may be viewed on the display or transferred to PC.
Fast Tracker™—Tag Identification System
HANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.
iButton. Tags are Easy to Install
Install the optional TAGs near your sampling points for quick and easy iButton. readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.
SKU | HI9829-02-web |
---|---|
Product Name | HI9829 Multiparameter pH/ISE/EC/DO/Turbidity Waterproof Meter with GPS option |
Quote Required | Yes |
pH Range | 0.00 to 14.00 pH |
pH Resolution | 0.01 pH |
pH Accuracy | ±0.02 pH |
pH Calibration | automatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer |
ORP Range | ±2000 mV |
ORP Resolution | 0.1 mV |
ORP Accuracy | ±1.0 mV |
ORP Calibration | automatic at one custom point (relative mV) |
mV Range | ±600.0 mV |
mV Resolution | 0.1 mV |
mV Accuracy | ±0.5 mV |
EC Range | 0 to 200 mS/cm (absolute EC up to 400 mS/cm) |
EC Resolution | Manual |
EC Accuracy | ±1% of reading or ±1 µS/cm whichever is greater |
EC Calibration | automatic single point, with six standard solutions (84 µS/cm, 1413 µS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point |
TDS Range | 0 to 400000 ppm (mg/L); (the maximum value depends on the TDS factor) |
TDS Resolution | Manual |
TDS Accuracy | ±1% of reading or ±1 ppm (mg/L), whichever is greater |
TDS Calibration | based on conductivity or salinity calibration |
Salinity (PSU) Range | 0.00 to 70.00 PSU |
Salinity (PSU) Resolution | 0.01 PSU |
Salinity (PSU) Accuracy | ±2% of reading or ±0.01 PSU whichever is greater |
Salinity (PSU) Calibration | based on conductivity calibration |
Salinity (Seawater Sigma) Range | 0.0 to 50.0 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Resolution | 0.1 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Accuracy | ±1 σt, σ₀, σ₁₅ |
Salinity (Seawater Sigma) Calibration | based on conductivity or salinity calibration |
Resistivity Range | 0 to 999999 Ω•cm; 0 to 1000.0 kΩ•cm; 0 to 1.0000 MΩ•cm |
Resistivity Resolution | dependent on resistivity reading |
Resistivity Calibration | based on conductivity calibration |
Dissolved Oxygen Range | 0.0 to 500.0%; 0.00 to 50.00 ppm (mg/L) |
Dissolved Oxygen Resolution | 0.1%; 0.01 ppm (mg/L) |
Dissolved Oxygen Accuracy | 0.0 to 300.0% saturation |
Dissolved Oxygen Calibration | automatic one or two points at 0 and 100% or one custom point |
Turbidity Range | 0.0 to 99.9 FNU; 100 to 1000 FNU |
Turbidity Resolution | 0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU |
Turbidity Accuracy | ±0.3 FNU or ±2 % of reading, whichever is greater |
Turbidity Calibration | Automatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom |
Temperature Range | -5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K |
Temperature Resolution | 0.01 K, 0.01 °C, 0.01 °F |
Temperature Accuracy | ±0.15 °C; ±0.27 °F; ±0.15 K |
Temperature Calibration | automatic at one custom point |
Temperature Compensation | automatic from -5 to 55 °C (23 to 131 °F) |
Ammonium Range | 0.02 to 200.0 ppm (as NH4+-N) |
Ammonium Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
Ammonium Accuracy | ±5 % reading or 2 ppm |
Ammonium Calibration | 1 or 2 point, 10 ppm and 100 ppm |
Chloride Range | 0.6 to 200.0 ppm Cl (as Cl- ) |
Chloride Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm |
Chloride Accuracy | ±5 % of reading or 2 ppm |
Chloride Calibration | 1 or 2 point, 10 ppm and 100 ppm |
Nitrate Range | 0.62 to 200.0 ppm Ni (as NO3 - -N) |
Nitrate Resolution | 0.01 ppm to 1 ppm 0.1 ppm to 200 ppm |
Nitrate Calibration | 1 or 2 point, 10 ppm and 100 ppm |
Logging Memory | 44,000 records (continuous logging or log-on-demand of all parameters) |
Logging Interval | one second to three hours |
Connectivity | USB (with HI 929829 software) |
Battery Type/Life | 1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration |
IP Protection | IP67 |
Environment | 0 to 50°C (32 to 122°F); RH max 100% |
Dimensions | 221 x 115 x 55 mm (8.7 x 4.5 x 2.2”) |
Weight | 750 g (26.5 oz.) |
GPS | 12 channel receiver 10 m (30 ft) accuracy |
Ordering Information | The HI9829 and HI98290 (GPS model) are supplied with a HI710140 hard carrying case, HI7612VDC adapter, HI7698292 probe maintenance kit, HI929829 PC application software, HI7698291 USB cable (PC to meter), HI710045 power supply cable, HI710046 cigarette lighter power cable, HI9829-25 quick calibration solution, HI920005 iButton with holder (5), HI7609829-1 pH/ORP sensor, HI7609829-2 galvanic DO sensor, HI7609829-3 EC sensor, HI7698290 short calibration beaker, HI7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual. |
Atmospheric Pressure Range | 450 to 850 mm Hg; 17.72 to 33.46 in Hg; 600.0 to 1133.2 mbar; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm; 60.00 to 113.32 kPa |
Atmospheric Pressure Resolution | 0.1 mm Hg; 0.01 in Hg; 0.1 mbar; 0.001 psi; 0.0001 atm; 0.01 kPa |
Atmospheric Pressure Accuracy | ±3 mm Hg within ±15% from calibration point |
Atmospheric Pressure Calibration | automatic at one custom point |