DEGSON PCKK4

分类: Din Rail Terminal Block 当前有货
欲了解更多详情,请游览我们的官方网站 mobicon.com.my

详情

DOWNLOAD DATASHEET
 

Item

Data

APPROVAL

 Certification Link

 Certification Link

Test standard

IEC/EN60947-7-1:2009 / UL1059

Pitch)                                     [mm]

6.20

Poles

01P

EN60947-7-1 Test data

VDE certificate NO. 40024860

Rated voltage                              [V]

500

Rated current                             [A]

32

Rated connection capacity(solid/stranded) [mm2]

0.2-4.0

Surge voltage category/pollution degree/material group

III/3/I

Rated impulse voltage                   [KV]

6

Rated torque                              [N.m]

0.5

UL1059Test data

UL File Number E228872

Use group

B

C

D

Rated voltage                             [V]

300

300

300

Rated current                            [A]

30

30

10

Rated connection capacity (solid/stranded) [AWG]

26-10

Rated torque                            [Lb. in]

5.4

General data

/

Screw

M3

Inflammability class UL94

V-0

Ambient temperature                       [℃]

-40~+105

Relative humidity

5%-95%

Inspection standard

MIL-STD-105E II

AQL

0.65

Warranty

12 months

Material and plating

/

Housing

PA66

Screws

Copper alloy,Ni plated

Contact

Copper alloy,Sn plated

Cage

Copper alloy,Ni plated

Wire connecting

Recommended stripping length 9-10mm;

For solid wire, stripping wire to the appointed length, then tightening with rated torque.

For stranded wire: stripping wire to the appointed length, mating with corresponding type of ferrule, then tightening with rated torque.

 

Tightening process should be steady, can’t use explosive force.

 

更多 MOBICON-REMOTE ELECTRONIC SDN BHD 相关资料
MOBICON-REMOTE ELECTRONIC SDN BHD
MOBICON-REMOTE ELECTRONIC SDN BHD Electronic Components Selangor, Penang, Test & Measurement Instruments Supply Kuala Lumpur (KL), Automation Parts Supplier Malaysia ~ MOBICON-REMOTE ELECTRONIC SDN BHD