The Reliable, Repeatable, Accurate Way to Check Bearings and Overall Vibration
Make go or no-go maintenance decisions with confidence. The Fluke 805 Vibration Meter is the most reliable vibration screening device available for frontline mechanical troubleshooting teams that need repeatable, severity-scaled readings of overall vibration and bearing condition.
What Makes the 805 the Best Choice?
Other useful features:
Vibration Meter | ||
Low frequency range (overall measurement) | 10 Hz to 1,000 Hz | |
High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz | |
Severity levels | Good, satisfactory, unsatisfactory, unacceptable | |
Vibration limit | 50 g peak (100 g peak-peak) | |
A/D converter | 16-bit | |
Signal to noise ratio | 80 dB | |
Sampling rate | Low frequency | 20,000 Hz |
High frequency | 80,000 Hz | |
Real time clock backup | Coin battery | |
Sensor | ||
Sensitivity | 100 mV g ±10% | |
Measurement range | 0.01 g to 50 g | |
Low frequency range (overall measurement) | 10 Hz to 1,000 Hz | |
High frequency range | 4,000 Hz to 20,000 Hz | |
Resolution | 0.01 g | |
Accuracy | At 100 Hz ±5% of measured value | |
Amplitude Units | ||
Acceleration | g, m/sec² | |
Velocity | in/sec, mm/sec | |
Displacement | mils, mm | |
Infrared Thermometer (Temperature Measurement) | ||
Range | -20°C to 200°C (-4°F to 392°F) | |
Accuracy | ±2°C (4°F) | |
Focal length | Fixed, at ~3.8 cm (1.5 in) | |
External sensor | ||
Fluke supports but does not provide external sensors | ||
Frequency range | 10 Hz to 1,000 Hz | |
Bias voltage (to supply power) | 20 VDC to 22 VDC | |
Bias current (to supply power) | Maximum 5 mA | |
Firmware | ||
External interfaces | USB 2.0 (full speed) communication | |
Data capacity | Database on internal flash memory | |
Upgrade | Through USB | |
Memory | Up to 3,500 measurements | |
Radiated Emission | ||
Electrostatic discharge: burst | Standard EN 61000-4-2 | |
Electromagnetic interference | Standard EN 61000-4-3 | |
RE | Standard CISPR 11, Class A | |
Environmental | ||
Operating temperature | -20°C to 50°C (-4°F to 122°F) | |
Storage temperature | -30°C to 80°C (-22°F to 176°F) | |
Operating humidity | 10% to 95% RH (non-condensing) | |
Operating/storage altitude | Sea level to 3,048 meters (10,000 feet) | |
IP rating | IP54 | |
Vibration limit | 500 g peak | |
Drop test | 1 meter | |
General Specifications | ||
Battery type | AA (2) Lithium Iron Disulfide | |
Battery life | 250 measurements | |
Size (L x W x H) | 24.1 x 7.1 x 5.8 cm (9.5 x 2.8 x 2.3 in) | |
Weight | 0.40 kg (0.89 lb) | |
Connectors | USB mini-B 7-pin, stereo audio output jack (3.5 mm Audio Plug), external sensor jack (SMB connector) |