详情
BRUSH GROMMET
AIR SEAL
Maintaining adequate underfloor static pressure is one of the most important aspects for successful cooling
of the data center. The Airseal brush grommet is intended for new installations to seal floor cutouts before
the installation of power or communication cables. “Bypass air” is conditioned air that does not reach the intake of IT equipment.
The elimination or reduction of “bypass air” is essential to the successful operation
of the cooling dynamics of the data center. Air-Brush is the economical choice in raised floor grommets.
-
Promotes Hot Aisle/Cold Aisle best practices
-
Increases overall room cooling capacity
-
Increases the underfloor static pressure
-
Improves airflow where it is needed
-
Can be used on new or existing Data Centre
-
Dimension: 201mm x 265mm x 44mm
KOLDLOK
KoldLok SplitLok Integral Grommet – Model #4040
-
Split Frame
-
Interlocking feature fastens the two halves together
-
Dry erase markable surface (non-permanent marker)
-
New and improved finish quality
-
Stronger material – high-impact ABS plastic
-
Easier installation
-
Smooth polished surface
-
Dimension: 279mm x 212mm x 42mm
KoldLok SplitLok Square Grommet – Model #5050
Square grommet for new or existing floor tiles.
-
Split Frame
-
Square Design
-
Interlocking feature fastens the two halves together
-
Dry erase markable surface (non-permanent marker)
-
New and improved finish quality
-
Stronger material – high-impact ABS plastic
-
Easier installation
-
Smooth polished surface
-
Dimensions:190.5mm x 187.71mm x 41.66mm
KoldLok Mini – Model #10077
Designed to seal small openings in new or existing raised floor cutouts either prior to the installation
of communications or power cabling or where cabling has already been installed.
Based on measurements at multiple data centers, on average 48% of valuable conditioned
air is not reaching the air intake of IT equipment due to unsealed floor openings.
This lost air, known as bypass airflow, contributes to IT equipment hot spots, cooling unit inefficiencies,
and increasing infrastructure costs. KoldLok® products specifically address bypass airflow
and its detrimental effects on data center cooling.
Dimension: 195mm x 145mm x 38mm
KoldLok Mini – Model #10077
Designed to seal small openings in new or existing raised floor cutouts either prior to the installation of communications
or power cabling or where cabling has already been installed.
Based on measurements at multiple data centers, on average 48% of valuable conditioned
air is not reaching the air intake of IT equipment due to unsealed floor openings.
This lost air, known as bypass airflow, contributes to IT equipment hot spots, cooling unit inefficiencies,
and increasing infrastructure costs. KoldLok® products specifically address bypass airflow and its detrimental effects on data center cooling.
Dimension: 195mm x 145mm x 38mm
更多 TH COMMUNICATION SDN. BHD. 相关资料