Sine wave output voltage
Selectable output frequency: 50/60Hz
High input-output isolation 3000Vrms
Three-phase synchronization
Remote inhibit
Input and output alarm
Railway version EN50155
Fire and smoke: EN45545-2 approved
DNV GL maritime type aproved product
Attribute | Value |
Input Voltage | 33.6 → 60V dc |
Output Voltage | 230V ac |
Output Power Continuous | 750 W, 750 VA |
Output Power Waveform | Pure Sine Wave |
MTBF | 160000h |
Output Current | 3.26A |
Length | 270.5mm |
Width | 52.5mm |
Depth | 160mm |
Weight | 2kg |
Minimum Temperature | -25 (50% Load) °C, -25 (Full Load) °C |
Mounting Type | Chassis Mount |
Output Electrical Phase | 3 |
Standards Met | 2014/30/EU, 2014/35/EU, EN 45545-2, EN 50121-3-2, EN 50121-4, EN 50155, EN 62368-1 |
Maximum Temperature | +55 (Full Load) °C, +70 (50% Load) °C |
Protection Features | Current Protection, Overload Protection, Polarity Protection, Power Protection |
Maximum Input Current | 270mA |
Number of Output Connections | 1 |
Cooling Method | Loading Controlled Cooling Fan |
Output Frequency Range | 50 → 60Hz |
Special Features | High Input-Output Isolation 3000 Vrms, Input & Output Alarm, Remote Inhibit, Selectable Output Frequency 50/60 Hz, Sine Wave Output Voltage, Three-Phase Synchronisation |