HIOKI IR5050 HIGH VOLTAGE INSULATION TESTER
Maximum 5kV Test Voltage - Up to 10 TΩ of Insulation Resistance Testing.
The IR5050 is a compact, lightweight, high-voltage insulation resistance tester capable of outputting up to 5 kV. Its unique measurement technology enables stable measurements of up to 10 TΩ.
Measurement parameters | • Insulation resistance • Leakage current • Voltage • Capacitance (DD function) |
---|---|
Max. rated voltage to terminals | 1000 V AC, 2000 V DC |
Max. rated voltage to ground | 1000 V (CAT IV), 600 V (CAT III) |
Operating temperature and humidity range | -20°C to 50 °C (*1) (no condensation) |
Storage temperature and humidity range | -25°C to 65°C (-13°F to 149°F), less than 80% RH (no condensation) |
Dustproof/waterproof | IP40 (with protector attached, excluding terminals) IP65 (CARRYING CASE C0212) |
Standards | EN61010 (safety), EN61326 (EMC), IEC 61557-1, IEC 61557-2 (Insulation resistance tester) |
Power supply | • LR6 (AA) alkaline battery × 8 • HR6 (AA) nickel-metal hydride (NiMH) rechargeable battery × 8 |
Continuous operating time (*2) | Approx. 5 hours without Z3210 installed; approx. 4 hours with Z3210 installed and using wireless communication |
Dimensions and weight | 195 mm (7.68 in.) W × 254 mm (10 in.) H × 89 mm (3.50 in.) D, 1.7 kg (59.97 oz.) (including batteries) |
Included accessories | Test lead L9850-01 ×1, Test lead L9850-02 ×1, Test lead L9850-03 ×1, Alligator clip L9851-01 ×1, Alligator clip L9851-02 ×1, Alligator clip L9851-03 ×1, Carrying Case C0212 ×1, LR6 Alkaline battery ×8, Instruction manual ×1, Operating precautions ×1 |
Insulation diagnosis | PI, DAR, DD, SV, Ramp, Timer |
---|---|
Others | Battery charge indicator, live circuit indicator, automatic power save, automatic discharge, backlight, buzzer, manual recording, logging recording, temperature and humidity input, elapsed time display, clock, filter, hardware filter, data-hold, system reset, USB communication (only when DT4900-01 is installed), wireless communication (only when Z3210 is installed), comparator, resistance gauge display, switching of insulation diagnosis function, breakdown cut-off. |
Test voltage range | DC 250 V to 5.20 kV DC | ||||
---|---|---|---|---|---|
User-set test voltage | 250 V to 1 kV: in 10 V increments; 1 kV to 5 kV: in 25 V increments | ||||
Test voltage preset | 250 V | 500 V | 1000 V | 2500 V | 5000 V |
Guaranteed accuracy range (1) | 0.00 MΩ02.50 GΩ ±5% rdg ±5 dgt | 0.00 MΩ05.00 GΩ ±5% rdg ±5 dgt | 0.00 MΩ010.0 GΩ ±5% rdg ±5 dgt | 0.00 MΩ025.0 GΩ ±5% rdg ±5 dgt | 0.00 MΩ050.0 GΩ ±5% rdg ±5 dgt |
Guaranteed accuracy range (2) | 2.51 GΩ0500 GΩ ±20% rdg | 5.01 GΩ01.00 TΩ ±20% rdg | 10.1 GΩ02.00 TΩ ±20% rdg | 25.1 GΩ05.00 TΩ ±20% rdg | 50.1 GΩ010.00 TΩ ±20% rdg |
Rated current | 1 mA to 1.2 mA | ||||
Short-circuit current | 2 mA or less | ||||
Possible number of measurements | 200 times or more on one set of fully-charged batteries |
Measurement range (auto) | 10 nA | 100 nA | 1000 nA | 10 μA | 100 μA | 1 mA |
---|---|---|---|---|---|---|
Display range | 0.00 nA to 9.99 nA | 9.0 nA to 99.9 nA | 90 nA to 999 nA | 0.90 μA to 9.99 μA | 9.0 μA to 99.9 μA | 90 μA to 999 μA (*3) 0.90 mA to 3.00 mA (*4) |
Resolution | 0.01 nA | 0.1 nA | 1 nA | 0.01 μA | 0.1 μA | *3: 1 μA *4: 0.01 mA |
Guaranteed accuracy range | 30 V to 1,000 V AC (45 Hz to 65 Hz), ±10 V to ±2,000 V DC |
---|---|
Accuracy | ±3% rdg. ±3 dgt. |
Input resistance | 500 kΩ or more (DC, 45 Hz to 65 Hz) |
Overload protection | 1100 V AC (1 min., between +/- terminals) 2200 V DC (1 min., between +/- terminals) |
Accuracy | ±10% rdg. ±5 nF (guaranteed accuracy range: 10.0 nF to 25.0 µF) | ||
---|---|---|---|
Measurement range | 100 nF | 1000 nF | 10 μF |
Display range | 0.0 nF to 99.9 nF | 100 nF to 999 nF | 1.00 μF to 9.99 μF (*5) 10.0 μF to 25.0 μF (*6) |
Resolution | 0.1 nF | 1 nF | *5: 0.01 μF *6: 0.1 μF |