Electrical Specification (23℃±5℃) |
|
|
DC Current: |
|
|
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
mA (0-4A) |
1mA |
±2.0%±3dgts |
DC 40A |
30A |
10mA |
±2.0%±3dgts |
DC 100A |
40A |
10mA |
±2.5%±3dgts |
DC 100A |
AC Current: |
|
|
|
|
(True RMS, Crest Factor < 3) |
|
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
50/60 Hz |
40 - 100Hz |
400mA |
0.1mA |
±1.5%±5dgts |
±2.0%±5dgts |
AC 40A |
|
|
50/60 Hz |
40 - 1KHz |
|
4000mA |
1mA |
±2.5%±5dgts |
±3.0%±5dgts |
AC 40A |
30A |
10mA |
±2.0%±5dgts |
±2.5%±5dgts |
AC 100A |
DC Voltage: |
|
|
|
|
(Input Impedance: 10M) |
|
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
400V |
0.1V |
±1.0%±2dgts |
DC 1000V |
AC Voltage: |
|
|
|
|
(Input Impedance: 10M, True RMS, Crest Factor < 3) |
|
|
Range |
Resolution |
Accuracy |
Overload Protection |
50/60 Hz |
40 - 1KHz |
400V |
0.1V |
±1.5%±4dgts |
±2.0%±5dgts |
AC 800V |
General Specifications: |
|
|
|
Conductor Size: |
23mm max. (approx.) |
|
|
Dimension (Box): |
183 (L) x 61.3 (W) x 35.6 (H) mm |
|
|
7.2" (L) x 2.5" (W) x 1.4" (H) |
|
|
Battery Type: |
two 1.5V SUM-3 |
|
|
Display: |
3 3/4 LCD with 40 seg. bargraph |
|
|
Range Selection: |
Manual |
|
|
Overload Indication: |
OL |
|
|
Power Consumption: |
15 mA (approx.) |
|
|
Low Battery Indication: |
|
|
|
Sampling Time: |
3 times/sec. (display) |
|
|
30 times/sec. (bargraph) |
|
|
Operating Temperature: |
-10C to 50C |
|
|
Operating Humidity: |
less than 85% relative |
|
|
Altitude: |
up to 2000M |
|
|
Storage Temperature: |
-20C to 60C |
|
|
Storage Humidity: |
less than 75% relative |
|
|
Weight: |
190g (battery included) |
|
|
Accessories: |
Carrying bag x 1 |
|
|
Users manual x 1 |
|
|
Batteries 1.5V x 2 |
|
|
Test leads x 1 |
|
|
|
|
|
|