Contains a highly isolated input system which ensures that signals are not corrupted
by noise from other channels. The GL840's inputs are suitable for combined
measurements from voltage, temperature, humidity, logic, and pulse signals.
The standard configuration has 20 analog input channels. It is expandable to
200 channels by adding optional 20 channels extension terminal base unit (B-566)
and input terminal units (B-564 or B-565).
Withstand voltage & Accuracy | Multi-input type (B-564) | Withstand-voltage type (B-565) | |
---|---|---|---|
Voltage | Input voltage range | 20 mV to 100 V | 20 mV to 100 V |
Max. voltage (Input - GND) | 60 Vp-p | 300 Vp-p | |
Temp. | Thermocouple | R, S, B, K, E, T, J, N, W (WRe5-26) | |
RTD (Resistance Temp. Detector) | Pt100 (IEC751), Pt1000 (IEC751), JPt100 (JIS) | ||
Accuracy | Voltage | ± 0.1% of F.S. | ± (0.05% of FS + 10μV) |
Temperature* | ± 1.55 ºC | ± 1.1 ºC |
* Accuracy rating for K-type thermocouple at 100˚C includes reference junction compensation.
Accuracy varies by temperature levels and thermocouple types.
Configuration for additional channels
Number of channels |
20 channels |
40 channels |
100 channels |
200 channels |
---|---|---|---|---|
GL840 unit (GL840-M or GL840-WV) |
1 set |
1 set |
1 set |
1 set |
Connection cable (B-567-05 or -20) |
N/A |
1 pc |
1 pc |
1 pc |
Terminal base (B-566) |
N/A |
2 sets |
5 sets |
10 sets |
Input terminal (B-564 or B-565 ) |
N/A |
1 set |
4 sets |
9 sets |
Input terminal blocks can be connected directly (in daisy chain), or using the B-565 cable(s).
This allows the input terminals to be placed in separate locations according to the
need of the application. The input terminal unit and the GL840 main body can be
extended by using an extended connections cable.
*If the signal is affected by noise, it may be required to use a slower sampling.
Digital sensors and input terminal/adapters for the GL100
connects to the GL840 directly
Supports 4-channels logic or pulse signal inputs. Pulse mode allows cumulative, instant,
or rotational values for industrial measurement capability with speed and flow.
Provides faster sampling rates for voltage measurements. Up to 10ms sampling speed
is achievable when limiting the number of channels in use.
Sampling Interval |
10ms | 20ms | 50ms | 100ms | 200ms | 500ms | 1s | 2s | |
---|---|---|---|---|---|---|---|---|---|
Number of channel |
1 | 2 | 5 | 10 | 20 | 50 | 100 | 200 | |
Measuring |
Voltage |
● | ● | ● | ● | ● | ● | ● | ● |
Temperature |
- | - | - | ● | ● | ● | ● | ● |
The new GL series enables reliable long term measurment with its
built-in 4GB flash memory and SD card slot for external storage devices.
The SD card slot supports an SDHC memory card of up to 32GB.
The captured data can be stored in GBD (Graphtec binary data) or CSV file format.
Capturing time* (when all 20 analog channels are being used with Logic/Pulse inputs turned off.)
Sampling |
10ms | 50ms | 100ms | 200ms | 500ms | 1s | 10s |
---|---|---|---|---|---|---|---|
GBD format |
31 days | 77 days | 95 days | 108 days | 270 days | Over 365 | Over 365 |
CSV format |
3 days | 11 days | 16 days | 21 days | 54 days | 109 days | Over 365 |
*Figures are approximate. File size of captured data is 2GB in GBD or CSV file format on this chart.
Sampling interval is limited by the number of channels in use. (10ms:1ch, 50ms:5ch, 100ms:10ch)
Limited sampling speed is available when digital sensors and GL100-WL are used as a remote monitoring device.
The most recent data is saved when the memory is configured in ring memory mode. (Number of capturing data is 1000 to 2000000 points)
Relay capture function
Data is
continuously
saved to multiple files up to 2GB
without losing any data until capturing
is stopped when the memory is
configured in the relay mode.
SD card can be replaced during data capturing when the sampling interval is 100ms or slower.
Useful Functions
The integrated data that is measured
by the digital sensors can be displayed
by a bar chart in the GL840 series.
Available GS sensors | Measurement | Unit |
---|---|---|
GS-TH (Temp/Humidity) sensor | Integrated temperature | ℃h |
GS-DPA-AC adapter with GS-Acxxx sensor (AC current/power) | Integrated power | kWh |
GS-LXUV (Illuminance/UV) sensor | Integrated illuminance | lxh or klxh |
Integrated UV | mW/cm2h |
Alarm signals can be placed using the four channel alarm output ports based on set conditions for each channel.
* Optional cable (B-513) is required.
Simple to use navigation screen
allows setting operation for
measurement and wireless LAN adapter.
Monitoring data
can be displayed in
waveform or digital form.
Parameter settings can be displayed
on the screen.
Choose from AC power supply, DC supply* or the rechargeable battery pack.*
* Optional accessories (B-514 or B-569) are required.
USB drive mode function enables data to be transferred to the PC from GL840 by drag & drop feature.
Monitoring data can be displayed in waveform or digital form. Parameter settings can be displayed on the screen.
Various functions are available using a network.
Web & FTP server function, FTP client function, NTP client function
Wireless measurement using wireless LAN (option)*
* Optional Wireless LAN unit is available in limited region.
Wireless LAN option enables the wireless communication with other device.
Connects to the GL100-WL wireless unit remotely when the GL840 is
set as an access point. When the GL840 is set as a station, PC and smart
devices will be able to access the WLAN unit directly.
Case 1 : Combining GL100-WL and GL840
Case 2 : Remote monitoring of GL840 by PC or Smart device
Case 3 : Remote monitoring of GL840 using Network
Case 4 : Remote monitoring of GL840 via Internet
GL100-WL can now be connected to the GL840 as a remote sensor using
the WLAN feature. You can expand your measurement variety by adding
the sensors available on the GL100-WL unit. The measured value by GL100-WL
will appear in a single file along with the measurement value from the GL840 main
inputs. GL840 will now take in direct information from the GL100-WL units.
GL840 supports up to five units of the GL100-WL.
Easily get the additional information that is required for the
multi channel temperature measurement.
Measurement data from GL100-WL,
GS sensor on the main unit can be
displayed as a waveform and digital value.
Measured data can
be monitored and
controlled via PC or a
smart device using
the applicaiton software.
Using a wireless LAN,
there is no needs to
connect by USB cable with the GL840.
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
Smart Device |
YES | YES | YES | N/A | N/A |
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
PC | YES | YES | YES | YES | N/A |
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
Smart Device |
YES | YES | YES | N/A | N/A |
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
Smart Device |
YES | YES | YES | N/A | N/A |
PC | YES | YES | YES | YES | N/A |
GL840 can be connected to a
LAN (Local Area Network) via
an wireless LAN access point.
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
Smart Device |
YES | YES | YES | N/A | N/A |
PC | YES | YES | YES | YES | YES |
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
Smart Device |
YES | YES | YES | N/A | YES |
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
PC | YES | YES | YES | YES | YES |
Using a router that supports
a dinamic DNS service, it enables
to monitor GL840 remotely via Internet.
In other words, it is possible to
contact your GL840 whereever you are !!
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
Smart Device |
N/A | N/A | N/A | N/A | YES |
PC | N/A | N/A | N/A | N/A | YES |
Display the data | Control the Start / Stop | Change the settings | Saves the data | Receives warning mail | |
---|---|---|---|---|---|
Smart Device |
YES | YES | YES | N/A | YES |
PC | YES | YES | YES | YES | YES |
The integrated data that is
measured by the digital sensors
can be displayed by a bar chart
in the GL840 series.
Available GS sensors | Measurement | Unit |
---|---|---|
GS-TH (Temp/Humidity) sensor | Integrated temperature | ℃h |
GS-DPA-AC adapter with GS-Acxxx sensor (AC current/power) | Integrated power | kWh |
GS-LXUV (Illuminance/UV) sensor | Integrated illuminance | lxh or klxh |
Integrated UV | mW/cm2h |
Alarm signals can be placed using the four channel alarm output ports based on set conditions for each channel.
* Optional cable (B-513) is required.
Simple to use navigation screen allows setting operation for measurement and wireless LAN adapter.
Choose from AC power supply, DC supply* or the rechargeable battery pack.*
* Optional accessories (B-514 or B-569) are required.
USB drive mode function enables data to be transferred to the PC from GL840 by drag & drop feature.
Monitoring data can be displayed in waveform or digital form. Parameter settings can be displayed on the screen.
Various functions are available using a network.
Web & FTP server function, FTP client function, NTP client function