UB400-12GM-E4-V1

UB400-12GM-E4-V1

Kategori: Ultrasonic Sensor Tersedia
RM 204.00 Untuk maklumat lanjut, lawati laman web rasmi kami di winstonelectric.com.my

Penerangan

Technical data                      

General Specifications
Sensing distance 30…400mm
Adjustment range 50…400mm
Unusable area 0…30mm
Standard target plate 100mm×100mm
Transducer frequency About 310kHz
Response delay About 50ms
Indicators/Operating means
LED blue Power on
LED yellow indication of the switching state
Flashing:program function object detected
LED red permanently red: Error Red,flashing:program
function,object not detected
Electrical specifications
Operating voltage U B 10…30VDC,ripple10%ss
No-load supply current ≤30mA
Input
Input type 1 TEACH-IN input Operating distance
A1:-U B …+1V,operating distanceA2:+6…
+ U B  Input impedance:>4.7KΩ
TEACH-IN programmable pulse :≥1S
Output
Output type 1 switch output E5,PNP NO/NC,programmable
Rated operational current 100mA,short-circuit/overload protected
Default setting Switching point A1:70mm Switching point A2: 800mm
Voltage drop ≤ 3V
Repeat accuracy ≤ 1%
Switching frequency f ≤ 8 HZ
Range hysteresis H 1% of the set operating distance
Temperature influence ± 1.5% of full-scale value
Ambient conditions
Ambient temperature -25…70℃(248...343K)
Storage temperature -40…85℃(233...358K)
Mechanical specifications
Protection grade IP67
Connection V1 connector(M12×1),4-pin
Material Housing brass,nickel-plated
Transducer epoxy resin/hollow glass sphere mixture;
Polyurethane foam
Weight 25g

Dimension                          

Adjusting the switching points        

The ultrasonic sensor features a switch output with two teachable switching points. These are set by applying the supply voltage - U B or + U B to the TEACH-IN input. The supply voltage must be applied to the TEACH-IN input for at least 1s.LEDs indicate whether the sensor has recognised the target during the TEACH-IN procedure. Switching point A1 is taught with - U B ,A2 with +U B. Five different output functions can be set.
1.  Window mode, normally-open function.
2.  Window mode, normally-closed function.
3.  One switching point,normally-open function
4. One switching point,normally-closed function.
5.  Detection of objet presence.
Switching point, Setting distance only after power on. The internal clock can assure can't be changed after 5 mins when power
on. If want to change the switching point, the user can only setting the request distance after power restart.

Lebih maklumat tentang Winston Resources
Winston Resources
Winston Resources Lab & Industrial Process Equipment Selangor, Electronic Components Supply Kuala Lumpur (KL), Processing Machine Supplier Malaysia ~ Winston Resources