HI84530-50 Low Range Titrant for Titratable Acidity in Water Mini Titrator

HI84530-50 Low Range Titrant for Titratable Acidity in Water Mini Titrator

Kategori: Titrants Stok Habis
Boleh Dibeli di Laman Web Rasmi
RM 165.00 Untuk maklumat lanjut, lawati laman web rasmi kami di hannamalaysia.com

Penerangan

The HI84530 Titratable Acidity for Water Analysis utilizes two different titrant solutions depending on the selected range when measuring acidity in water.

 

The HI84530-50 is a 120 mL bottle of low range titrant with an expected range between 15 to 400 mg/L as CaCO3. The titrant solution is pre-standardized, making titrations fast, accurate, and easy to perform.










Details

The HI84530-50 is a 120 mL bottle of alkaline titrant solution that is used for low range (15 to 400 mg/L as CaCO3) determination of acidity in water. 

The HI84530 mini titrator is designed to determine the acidity of waters by potentiometric titration in both a low range (15 to 400 mg/L as CaCO3) and high range (300 to 4000 mg/L as CaCO3). Both total and strong acidity can be determined by the HI84530. If the measured pH is lower than 3.7 both total and strong acidity can be determined. If the sample is greater than pH 3.7 then only total acidity can be determined.

The endpoint of an acid base titration corresponds to the complete neutralization of the acids present. Water acidity results from strong and weak acids as well as from the hydrolysis of salts. Due to these more complex mixtures, endpoints for water acidity are arbitrarily fixed on practical considerations. Unpolluted surface waters contain carbon dioxide as the main acidic component, and titration of these samples corresponds to the stoichiometric neutralization of carbonic acid with sodium hydroxide. The titration to pH 8.3 represents total acidity. The titration to pH 3.7 represents strong acidity from polluted water. If the samples are suspected to contain hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese), it is necessary to pretreat the samples with HI84530-60 reagent.

Replacement reagents required to operate the HI84530 include:

 

Low Range - 15 to 400 mg/L as CaCO3

High Range - 300 to 4000 mg/L as CaCO3

Pump calibration standard

HI84530-55

HI84530-55

Titrant solution

HI84530-50

HI84530-51

Additional reagent*

HI84530-60

HI84530-60

* Used with samples containing hydrolyzable salts or polyvalent cations (such as chromium, iron, manganese)

 

Specifications

Package bottles
Size 120 mL
Quantity 1

















Lebih maklumat tentang Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd
Hanna Instruments (M) Sdn Bhd Measuring Instruments Selangor, Photometers Supply Penang, Sabah, Test Equipments Supplier Malaysia ~ Hanna Instruments (M) Sdn Bhd