MZ meters are flow. The flow of gas turns the turbine wheel, and thus the rotating speed of the turbing is proportional to the linear speed of the gas.
The movement is mechanically transmitted to the totaliser through a magnetic coupling.
Key Benefits
Intrinsic Safety Approval | L. C. I. E 06 ATEX 6031 X | |
Flow Rate | From 6 m3/h to 2500 m3/h | |
Nominal Diameters | From DN 2'' to 8'' DN50 to DN200 | |
Material | Ductile iron | |
Compliant with the pressure equipment directiv 97/23/EC | ||
Maximum Working Pressure | Up to 40 bar depending on flanging | |
Temperature Range | Ambient: | -30ºC to +60ºC |
Gas: | -30ºC to +60ºC | |
Storage temperature: | -40ºC to +70ºC | |
Metrology | The tolerance of acceptation is +/-1.5% from Qmin to Qmax. |